Publication:
Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles

No Thumbnail Available
Date
2011-03-01T00:00:00Z
Authors
Oguz, Yener
Saglam, Haci
Dolanmaz, DOĞAN
Uckan, Sina
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue

Metrics

Search on Google Scholar

Abstract
Ten unembalmed adult sheep mandibles were used. The mandibles were sectioned in the midline, followed by sagittal split ramus osteotomies to obtain 20 hemimandibles. Each distal segment was advanced 5 mm on each hemimandible. Ten of the specimens were fixed with 4-hole extended 2.0 mm titanium miniplates and screws and the other 10 were fixed with 4-hole extended 2.0 min locking miniplates/screws. Each fixed specimen was mounted on a servo-hydraulic testing unit with the fixation device, and was tested to a range of forces of 0-140N. The displacement values (mm) under 20, 60, 120, and 140N were compared with the help of the Mann Whitney U-test, and there were no significant differences between them at any force tested. Locking miniplate/screws and standard miniplate/screws showed similar displacement values at the range of forces tested. (C) 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Description
Keywords
Citation
Oguz Y., Saglam H., Dolanmaz D., Uckan S., -Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles-, BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, cilt.49, ss.135-137, 2011
Collections
Page Views

0

File Downloads

0

Sustainable Development Goals