Publication: Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles
dc.contributor.author | Oguz, Yener | |
dc.contributor.author | Saglam, Haci | |
dc.contributor.author | Dolanmaz, DOĞAN | |
dc.contributor.author | Uckan, Sina | |
dc.contributor.institutionauthor | DOLANMAZ, DOĞAN | |
dc.date.accessioned | 2020-10-22T15:52:54Z | |
dc.date.available | 2020-10-22T15:52:54Z | |
dc.date.issued | 2011-03-01T00:00:00Z | |
dc.description.abstract | Ten unembalmed adult sheep mandibles were used. The mandibles were sectioned in the midline, followed by sagittal split ramus osteotomies to obtain 20 hemimandibles. Each distal segment was advanced 5 mm on each hemimandible. Ten of the specimens were fixed with 4-hole extended 2.0 mm titanium miniplates and screws and the other 10 were fixed with 4-hole extended 2.0 min locking miniplates/screws. Each fixed specimen was mounted on a servo-hydraulic testing unit with the fixation device, and was tested to a range of forces of 0-140N. The displacement values (mm) under 20, 60, 120, and 140N were compared with the help of the Mann Whitney U-test, and there were no significant differences between them at any force tested. Locking miniplate/screws and standard miniplate/screws showed similar displacement values at the range of forces tested. (C) 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved. | |
dc.identifier.citation | Oguz Y., Saglam H., Dolanmaz D., Uckan S., -Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles-, BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, cilt.49, ss.135-137, 2011 | |
dc.identifier.doi | 10.1016/j.bjoms.2009.11.014 | |
dc.identifier.scopus | 79951674037 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/23565 | |
dc.identifier.wos | WOS:000288629300011 | |
dc.identifier.yoksis | 2157942 | |
dc.title | Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | 419515aa-1d84-43d7-8a7f-05d1c18294d1 | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 | |
relation.isAuthorOfPublication | 3702a728-af19-4120-bfb8-ef15274fb493 | |
relation.isAuthorOfPublication.latestForDiscovery | 3702a728-af19-4120-bfb8-ef15274fb493 |