Domestic electric drills in the service of orthopaedic surgery: a potential and preventable source of surgical site infections

Thumbnail
Göster/Aç
38- Domestic electric drills in the service of orthopaedic surgery a potential and preventable source of surgical site infections..pdf (140.0Kb)
Tarih
2012-11-01
Yazar
Kucukdurmaz, FATİH
SEN, Cengiz
Tuncay, Ibrahim
Akkoyunlu, YASEMİN
IMREN, Yunus
Danışman
Türü
Article
Üst veri
Tüm öğe kaydını göster
Özet
Objective: We aimed to assess the contamination potential of the exhaust air from venting ports of running domestic electric drills which are commonly used in orthopaedic surgeries by means of both microbiological sampling and particle counting. Methods: In an empty operating room, the exhaust air from five running sterile domestic electric drills measured using a particle counter and microbiological sampling was made via aspirating isolator with colony formations noted for a 2-week period. International Organization for Standardization (ISO) 14644 criteria were implemented with respect to the sterility standards. Results: All of the drills produced statistically significantly higher levels of particles than the ambient air (p<0.01). There was no statistically significant difference in the number of collected particles among drills (p>0.05). No bacterial growth was detected in microbiological sampling via blood agar medium in the ambient air. Conversely, Staphylococcus epidermidis, Micrococcus luteus, and Staphylococcus capitis were isolated from the exhaust air of all running drills. There was no correlation between the number of particles produced by drills and the microbiological sampling. Conclusion: Domestic electric drills are not safe and may be a direct source of surgical site infection, as the use or re-use of these drills during orthopaedic surgery increases the risk of infection with contaminated aerosols that are produced by these devices.
Konu
surgery
Bağlantı
https://hdl.handle.net/20.500.12645/2305
Koleksiyonlar
  • Scopus İndeksli Yayınlar Koleksiyonu [4458]
  • Tıp Fakültesi [2546]
  • WoS İndeksli Yayınlar Koleksiyonu [5222]
  • Yayınlar - Eserler [10057]

BEZMIALEM VAKIF UNIVERSITY

About us |Policies | Library | Contact us | Send Feedback | Sitemap | Admin

Bezmialem Vakıf Üniversitesi, Adnan Menderes Bulvarı Vatan Caddesi 34093 Fatih, İstanbul / TURKEY
Copyright © Bezmialem Vakıf Üniversitesi

Creative Commons Lisansı
Bezmialem Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

OpenAccess@BVU

Support by  UNIREPOS


Bezmialem Kütüphane


OpenAccess@BVU validated by OpenAIRE

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile göreErişim Hakkına GöreDanışmana GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile göreErişim Hakkına GöreDanışmana Göre

Hesabım

GirişKayıt

BEZMIALEM VAKIF UNIVERSITY

About us |Policies | Library | Contact us | Send Feedback | Sitemap | Admin

Bezmialem Vakıf Üniversitesi, Adnan Menderes Bulvarı Vatan Caddesi 34093 Fatih, İstanbul / TURKEY
Copyright © Bezmialem Vakıf Üniversitesi

Creative Commons Lisansı
Bezmialem Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

OpenAccess@BVU

Support by  UNIREPOS