Publication:
Domestic electric drills in the service of orthopaedic surgery: a potential and preventable source of surgical site infections

dc.contributor.authorKucukdurmaz, FATİH
dc.contributor.authorIMREN, Yunus
dc.contributor.authorAkkoyunlu, YASEMİN
dc.contributor.authorTuncay, Ibrahim
dc.contributor.authorSEN, Cengiz
dc.contributor.institutionauthorKÜÇÜKDURMAZ, FATİH
dc.contributor.institutionauthorAKKOYUNLU, YASEMİN
dc.contributor.institutionauthorTUNCAY, İBRAHİM
dc.date.accessioned2019-10-05T13:31:50Z
dc.date.available2019-10-05T13:31:50Z
dc.date.issued2012-11-01
dc.description.abstractObjective: We aimed to assess the contamination potential of the exhaust air from venting ports of running domestic electric drills which are commonly used in orthopaedic surgeries by means of both microbiological sampling and particle counting. Methods: In an empty operating room, the exhaust air from five running sterile domestic electric drills measured using a particle counter and microbiological sampling was made via aspirating isolator with colony formations noted for a 2-week period. International Organization for Standardization (ISO) 14644 criteria were implemented with respect to the sterility standards. Results: All of the drills produced statistically significantly higher levels of particles than the ambient air (p<0.01). There was no statistically significant difference in the number of collected particles among drills (p>0.05). No bacterial growth was detected in microbiological sampling via blood agar medium in the ambient air. Conversely, Staphylococcus epidermidis, Micrococcus luteus, and Staphylococcus capitis were isolated from the exhaust air of all running drills. There was no correlation between the number of particles produced by drills and the microbiological sampling. Conclusion: Domestic electric drills are not safe and may be a direct source of surgical site infection, as the use or re-use of these drills during orthopaedic surgery increases the risk of infection with contaminated aerosols that are produced by these devices.en
dc.identifier10.1007/s10620-008-0535-0
dc.identifier.citationKucukdurmaz F., IMREN Y., Akkoyunlu Y., Tuncay I., SEN C., -Domestic electric drills in the service of orthopaedic surgery: a potential and preventable source of surgical site infections-, ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, cilt.46, ss.455-459, 2012
dc.identifier.doi10.3944/aott.2012.2794
dc.identifier.pubmed23428762
dc.identifier.scopus84875326283
dc.identifier.urihttps://hdl.handle.net/20.500.12645/2305
dc.identifier.wosWOS:000319231900010
dc.language.isoen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectsurgery
dc.titleDomestic electric drills in the service of orthopaedic surgery: a potential and preventable source of surgical site infections
dc.typeArticle
dspace.entity.typePublication
local.article.journalnameDIGESTIVE DISEASES AND SCIENCES
local.avesis.id37f1c0cc-e9ec-4392-84a6-88fe8fbfca3d
local.avesis.response2175
local.indexed.atPubMed
local.indexed.atWOS
local.indexed.atScopus
local.org.facultyTıp Fakültesi
local.publication.isinternational1
relation.isAuthorOfPublication5545e8b7-75a3-4fee-b2ed-53db0a437463
relation.isAuthorOfPublicationfc9e6e5e-089f-4a24-bc0e-7003bbed7005
relation.isAuthorOfPublication3e190620-9fed-4601-b2d2-56f6d609e355
relation.isAuthorOfPublication.latestForDiscoveryfc9e6e5e-089f-4a24-bc0e-7003bbed7005

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
38- Domestic electric drills in the service of orthopaedic surgery a potential and preventable source of surgical site infections..pdf
Size:
140.09 KB
Format:
Adobe Portable Document Format
Description: