Publication:
Assessment of Liver Fibrosis with Diffusion-Weighted Magnetic Resonance Imaging Using Different b-values in Chronic Viral Hepatitis

Thumbnail Image

Organizational Units

Program

Authors

KOCAKOÇ, ERCAN
Bakan, Ayse Ahsen
Poyrazoglu, Orhan Kursat
Dagli, Adile Ferda
Gul, Yeliz
Cicekci, Mehtap
BAHÇECİOĞLU, İBRAHİM HALİL

Advisor

Language

Publisher

Journal Title

Journal ISSN

Volume Title

Abstract

Objective: To examine the effectiveness of apparent diffusion coefficient (ADC) values and to compare the reliability of different b-values in detecting and identifying significant liver fibrosis. Subjects and Methods: There were 44 patients with chronic viral hepatitis (CVH) in the study group and 30 healthy participants in the control group. Diffusion-weighted magnetic resonance imaging (DWI) was performed before the liver biopsy in patients with CVH. The values of ADC were measured with 3 different b-values (100, 600, 1,000 s/mm(2)). In addition, liver fibrosis was classified using the modified Ishak scoring system. Liver fibrosis stages and ADC values were compared using areas under the receiver-operating characteristic (ROC) curve. Results: The study group-s mean ADC value was not statistically significantly different from the control group-s mean ADC value at b = 100 s/mm(2) (3.69 +/- 0.5 x 10(-3) vs. 3.7 +/- 0.3 x 10(-3) mm(2)/s) and b = 600 s/mm(2) (2.40 +/- 0.3 x 10(-3) vs. 2.5 +/- 0.5 x 10(-3) mm(2)/s). However, the study group-s mean ADC value (0.99 +/- 0.3 x 10(-3) mm(2)/s) was significantly lower than that of the control group (1.2 +/- 0.1 x 10(-3) mm(2)/s) at b = 1,000 s/mm(2). With b = 1,000 s/mm(2) and the cutoff ADC value of 0.0011 mm(2)/s for the diagnosis of liver fibrosis, the mean area under the ROC curve was 0.702 +/- 0.07 (p = 0.0015). For b = 1,000 s/mm(2) and the cutoff ADC value of 0.0011 mm(2)/s to diagnose significant liver fibrosis (Ishak score = 3), the mean area under the ROC curve was 0.759 +/- 0.07 (p = 0.0001). Conclusion: Measurement of ADC values by DWI was effective in detecting liver fibrosis and accurately identifying significant liver fibrosis when a b-value of 1,000 s/mm(2) was used. (C) 2015 S. Karger AG, Basel

Description

Source:

Keywords:

Keywords

Citation

KOCAKOÇ E., Bakan A. A. , Poyrazoglu O. K. , Dagli A. F. , Gul Y., Cicekci M., BAHÇECİOĞLU İ. H. , -Assessment of Liver Fibrosis with Diffusion-Weighted Magnetic Resonance Imaging Using Different b-values in Chronic Viral Hepatitis-, MEDICAL PRINCIPLES AND PRACTICE, cilt.24, ss.522-526, 2015

Endorsement

Review

Supplemented By

Referenced By

0

Views

11

Downloads

View PlumX Details


Sustainable Development Goals

Thumbnail Image
Goal