Publication: Inadequate shear bond strengths of self-etch, self-adhesive systems for secure orthodontic bonding
Program
Authors
Authors
Isman, Eren
Karaarslan, Emine Sirin
Oksayan, Ridvan
Tuncdemir, Ali Riza
Usumez, Serdar
ADANIR, NEJDET
Cebe, Mehmet Ata
Advisor
Language
Type
Publisher
Journal Title
Journal ISSN
Volume Title
Abstract
This study evaluated the shear bond strength (SBS) of a traditional orthodontic bracket bonding agent (Transbond XT) against two self-etch, self-adhesive systems (Maxcem Elite and Vertise Flow). Sixty premolar teeth and sixty brackets were randomly and equally divided into five groups: Transbond XT (TXT) as the control, Maxcem Elite (ME) without etching, ME with etching (ME/Etch), Vertise Flow (VF) without etching, and VF with etching (VF/Etch). Respective SBS results of the five groups were 9.86 +/- 3.20, 4.67 +/- 2.94, 7.82 +/- 2.56, 2.55 +/- 0.77, and 7.89 +/- 1.17 MPa. SBS values of the new self-etch adhesive systems were significantly lower than the traditional etch-and-rinse control (p0.005). After debonding, ARI scores -0- and -1- were predominant in non-etched ME and VF groups. It was concluded that new self-etch, self-adhesive bonding systems require additional phosphoric acid application to achieve comparable SBS values as the traditional orthodontic bonding agent.
Description
Source:
Keywords:
Keywords
Citation
Isman E., Karaarslan E. S. , Oksayan R., Tuncdemir A. R. , Usumez S., ADANIR N., Cebe M. A. , -Inadequate shear bond strengths of self-etch, self-adhesive systems for secure orthodontic bonding-, DENTAL MATERIALS JOURNAL, cilt.31, ss.947-953, 2012