Publication: The use of a liner under different bulk-fill resin composites: 3D GAP formation analysis by x-ray micro-computed tomography
dc.contributor.author | OĞLAKÇI, BURCU | |
dc.contributor.author | Kazak, Magrur | |
dc.contributor.author | DÖNMEZ, NAZMİYE | |
dc.contributor.author | Dalkilic, Evrim | |
dc.contributor.author | KÖYMEN, SAFİYE SELİN | |
dc.contributor.institutionauthor | OĞLAKÇI, BURCU | |
dc.contributor.institutionauthor | KAZAK, MAĞRUR | |
dc.contributor.institutionauthor | DÖNMEZ, NAZMİYE | |
dc.contributor.institutionauthor | DALKILIÇ, EVRİM | |
dc.contributor.institutionauthor | KÖYMEN, SAFİYE SELİN | |
dc.date.accessioned | 2020-01-13T20:59:14Z | |
dc.date.available | 2020-01-13T20:59:14Z | |
dc.date.issued | 2020-01-01T00:00:00Z | |
dc.description.abstract | Gap formation of composite resin restorations is a serious shortcoming in clinical practice. Polymerization shrinkage stress exceeds the tooth-restoration bond strength, and it causes bacterial infiltration within gaps between cavity walls and the restorative material. Thus, an intermediate liner application with a low elastic modulus has been advised to minimize polymerization shrinkage as well as gap formation. Objective: The purpose of this in vitro study was to assess gap formation volume in premolars restored with different bulk-fill composites, with and without a resin-modified glass-ionomer cement (RMGIC) liner, using x-ray micro-computed tomography (micro-CT). Methodology: Sixty extracted human maxillary premolars were divided into six groups according to bucco-palatal dimensions (n=10). Standardized Class II mesio-occluso-distal cavities were prepared. G-Premio Bond (GC Corp., Japan) was applied in the selective-etch mode. Teeth were restored with high-viscosity (Filtek Bulk Fill, 3M ESPE, USA)-FB, sonic-activated (SonicFill 2, Kerr, USA)-SF and low viscosity (Estelite Bulk Fill Flow, Tokuyama, Japan)- EB bulk-fill composites, with and without a liner (Ionoseal, Voco GmbH, Germany)-L. The specimens were subjected to 10,000 thermocycles (5-55oC) and 50,000 simulated chewing cycles (100 N). Gap formation based on the volume of black spaces at the tooth-restoration interface was quantified in mm3 using micro-computed tomography (SkyScan, Belgium), and analyses were performed. Data were analyzed using repeated-measures ANOVA and the Bonferroni correction test (p < 0.05). Results: The gap volume of all tested bulk-fill composites demonstrated that Group SF (1.581±0.773) had significantly higher values than Group EB (0.717±0.679). Regarding the use of a liner, a significant reduction in gap formation volume was observed only in Group SFL (0.927±0.630) compared with Group SF (1.581±0.773). Conclusion: It can be concluded that different types of bulk-fill composite resins affected gap formation volume. Low-viscosity bulk-fill composites exhibited better adaptation to cavity walls and less gap formation than did sonic-activated bulk-fill composites. The use of an RMGIC liner produced a significant reduction in gap formation volume for sonic-activated bulk-fill composites. | en |
dc.identifier.citation | OĞLAKÇI B., Kazak M., DÖNMEZ N., Dalkilic E., KÖYMEN S. S. , -The use of a liner under different bulk-fill resin composites: 3D GAP formation analysis by x-ray micro-computed tomography-, Journal of Applied Oral Science, cilt.28, 2020 | |
dc.identifier.doi | 10.1590/1678-7757-2019-0042 | |
dc.identifier.pubmed | 31778443 | |
dc.identifier.scopus | 85075610682 | |
dc.identifier.uri | https://openaccess.bezmialem.edu.tr/handle/20.500.12645/12265 | |
dc.identifier.wos | WOS:000499799700001 | |
dc.language.iso | en | |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.title | The use of a liner under different bulk-fill resin composites: 3D GAP formation analysis by x-ray micro-computed tomography | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | 2b758ad4-46f3-4ae8-881b-2375d2a0e7bb | |
local.indexed.at | PubMed | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 | |
relation.isAuthorOfPublication | dc13c663-2de3-4b9c-88f2-f6c37e1a4dd9 | |
relation.isAuthorOfPublication | 005d1f63-db19-41e5-90d7-934a0c184fe3 | |
relation.isAuthorOfPublication | 290534fc-5729-4123-86c9-b3d70bded178 | |
relation.isAuthorOfPublication | 05592be3-8323-4273-bfff-96d4c4775aa8 | |
relation.isAuthorOfPublication | 16947d06-38c3-4602-983d-c5e178882be5 | |
relation.isAuthorOfPublication.latestForDiscovery | 05592be3-8323-4273-bfff-96d4c4775aa8 |
Files
Original bundle
1 - 1 of 1
- Name:
- 40- The use of a liner under different bulk-fill resin composites 3D GAP formation analysis by x-ray microcomputed tomography.pdf
- Size:
- 1.45 MB
- Format:
- Adobe Portable Document Format
- Description: