dc.description.abstractIntroduction Incorrect positioning is one of the main factors for glenoid component loosening in reverse shoulder arthroplasty and component placement can be challenging. This study aimed to assess whether Patient-Specific Instrumentation (PSI) provides better guide pin positioning accuracy and is superior to standard guided and freehand instrumentation methods in cases of glenoid bone deformity. Materials and Methods Based on the Walch classification, five different scapula types were acquired by computed tomography (CT). For each type, two different surgeons placed a guide pin into the scapula using three different methods: freehand method, conventional non-patient-specific guide, and PSI guide. Each method was repeated five times by both surgeons. In these experiments, a total of 150 samples of scapula models were used (5 x 2 x 3 x 5 = 150). Post-operative CT scans of the samples with the guide pin were digitally assessed and the accuracy of the pin placement was determined by comparison to the preoperative planning on a three-dimensional (3D) model. Results The PSI method showed accuracies to the preoperative plan of 2.68 (SD 2.10) degrees for version angle (p < .05), 2.59 (SD 2.68) degrees for inclination angle (p < .05), and 1.55 (SD 1.26) mm for entry point offset (p < .05). The mean and standard deviation errors compared to planned values of version angle, inclination angle, and entry point offset were statistically significant for the PSI method for the type C defected glenoid and non-arthritic glenoid. Conclusion Using the PSI guide created by an image processing software tool for guide pin positioning showed advantages in glenoid component positioning over other methods, for defected and intact glenoid types, but correlation with clinical outcomes should be examined.
dc.identifier.citationSadeghi M. M. , KEÇECİ E. F. , KAPICIOĞLU M., Aralasmak A., Tezgel O., BAŞARAN M. A. , YILDIZ F., Bilsel K., -Three dimensional patient-specific guides for guide pin positioning in reverse shoulder arthroplasty: An experimental study on different glenoid types-, JOURNAL OF ORTHOPAEDIC SURGERY, cilt.30, sa.1, 2022
dc.identifier.doi10.1177/10225536221079432
dc.identifier.scopus85125426933
dc.identifier.urihttp://hdl.handle.net/20.500.12645/30472
dc.identifier.wosWOS:000765352200001
dc.titleThree dimensional patient-specific guides for guide pin positioning in reverse shoulder arthroplasty: An experimental study on different glenoid types
dc.typeArticle
dspace.entity.typePublication
local.avesis.id5fae7378-9aee-450f-adaa-a9d6871f7711
local.indexed.atWOS
local.indexed.atScopus
local.publication.isinternational1
relation.isAuthorOfPublication33bea6eb-2819-4537-8544-beab26dc66f0
relation.isAuthorOfPublication916dd84c-0db6-43c4-8168-c6c875f27bbe
relation.isAuthorOfPublication62fa4380-d04e-462f-964d-3d586ffd68dc
relation.isAuthorOfPublicationdb1859ad-a3b3-4299-8b42-89a62b377d7d
relation.isAuthorOfPublication.latestForDiscovery62fa4380-d04e-462f-964d-3d586ffd68dc

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Three dimensional patient-specific guides for guide pin positioning in reverse shoulder arthroplasty.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format
Description: