Publication:
The Effects of Thermo-mechanical Aging on Microleakage in Composite Restorations Polymerized Using One New Generation and Two Conventional Led Light Curing Units

dc.contributor.authorDönmez, Nazmiye
dc.contributor.authorŞeşen Uslu, Yeşim
dc.contributor.authorSiso, Şeyda Hergüner
dc.contributor.authorToprak, Ali
dc.contributor.institutionauthorDÖNMEZ, NAZMİYE
dc.contributor.institutionauthorTOPRAK, ALİ
dc.date.accessioned2021-02-01T20:59:19Z
dc.date.available2021-02-01T20:59:19Z
dc.date.issued2021-01-01T00:00:00Z
dc.description.abstractObjective: This study aimed to evaluate the effects of thermomechanical aging (TMA) on the microleakage scores of Class V composite restorations polymerized using one new generational and two conventional light emitting diodes (LED) light curing units (LCU). Methods: Class V cavities were prepared and restored on the buccal and lingual surfaces of 60 extracted human premolar teeth using a dental phantom head to simulate clinical conditions. After application of the adhesive system (Optibond Solo Plus, Kerr, USA) using total etch procedures. the cavities were restored with composite resin (Herculite XRV. Kerr, USA) using one new generational (Demi Ultracapacitor, Kerr, USA) and two conventional (Valo Cordless, USA and BA Optima International, UK) LED light devices. The restored teeth were then subdivided into the test (underwent TMA) and control (did not undergo TMA) groups, and the specimens were stained with 0.5% basic fuchsin dye and sectioned. Dye penetration was scored using a stereomicroscope at 40x magnification. Differences between groups were compared using the Kruskal-Wallis, Mann-Whitney U, and Wilcoxon Signed Ranks tests (p<0.05). Results: Comparison of the test and control groups by the LCUs used for polymerization showed a statistically significant difference in microleakage scores between the two (p<0.05). However, no differences in scores were observed between the new generational and two conventional LED LCUs (p>0.05). Conclusion: Thermal and mechanical aging procedures increased microlcakage in Class V composite estorations, regardless of the light curing unit used.
dc.identifier.citationDönmez N., Şeşen Uslu Y., Siso Ş. H. , Toprak A., -The effects of thermo-mechanıcal agıng on mıcroleakage of composıte restoratıons polymerızed wıth a new generatıon vs two conventıonal led lıgth curıng unıts-, Bezmialem Science , cilt.9, ss.91-97, 2021
dc.identifier.doi10.14235/bas.galenos.2020.3806
dc.identifier.trdizindoi.org/10.14235/bas.galenos.2020.3806
dc.identifier.trdizin425227
dc.identifier.urihttp://hdl.handle.net/20.500.12645/28227
dc.identifier.wosWOS:000613760800016
dc.subjectOral simulation
dc.subjectthermo-mechanical aging
dc.subjectLED light curing units
dc.subjectmicroleakage
dc.subjectclass V cavity
dc.titleThe Effects of Thermo-mechanical Aging on Microleakage in Composite Restorations Polymerized Using One New Generation and Two Conventional Led Light Curing Units
dc.typeArticle
dspace.entity.typePublication
local.avesis.id243a458c-b883-4fe7-81e9-05c161a5d558
local.publication.isinternational1
relation.isAuthorOfPublication290534fc-5729-4123-86c9-b3d70bded178
relation.isAuthorOfPublicationdbd19639-3d50-40a5-9a13-eb615691f6e4
relation.isAuthorOfPublication.latestForDiscovery290534fc-5729-4123-86c9-b3d70bded178
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The Effects of Thermo-mechanical Aging on Microleakage in Composite Restorations.pdf
Size:
442.74 KB
Format:
Adobe Portable Document Format
Description: