Person:
DALKILIƇ, EVRIM

Loading...
Profile Picture
Status
Organizational Units
Job Title
First Name
EVRIM
Last Name
DALKILIƇ
Name
Email Address
Birth Date

Search Results

Now showing 1 - 10 of 12
  • PublicationMetadata only
    The color change of a novel single-shade composite immersed in different beverages.
    (2022-12-01) Fazlıoğlu L.; OğlakƧı B.; Ɩzduman Z. C.; DalkılıƧ E.; FAZLIOĞLU, LEYLA; OĞLAKƇI, BURCU; ƖZDUMAN, ZƜMRƜT CEREN; DALKILIƇ, EVRIM
  • PublicationMetadata only
    The Effect of Different Intermediary Layer Materials Under Resin Composite Restorations on Volumetric Cuspal Deflection, Gap Formation, and Fracture Strength.
    (2022-11-28) Deger C.; Ɩzduman Z. C.; Oglakci B.; Eliguzeloglu Dalkilic E.; DALKILIƇ, EVRIM
  • PublicationOpen Access
    Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study
    (2019-01-01T00:00:00Z) ƖZDUMAN, ZƜMRƜT CEREN; Kazak, Magrur; FÄ°LDİŞİ, MEHMET ALÄ°; ƖZLEN, RƜMEYSA HATÄ°CE; DALKILIƇ, Evrim; DƖNMEZ, NAZMÄ°YE; ƖZDUMAN, ZƜMRƜT CEREN; FÄ°LDİŞİ, MEHMET ALÄ°; ƖZLEN, RƜMEYSA HATÄ°CE; DALKILIƇ, EVRIM; DƖNMEZ, NAZMÄ°YE
    Objective: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. Materials-methods: For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n = 5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n = 12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey's HSD test. The data from the top surface of specimens' microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-Whitney U tests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p < 0.05). Results: The B/T microhardness ratio results revealed no significant differences between groups (p > 0.05). Comparing the microhardness values of the composites' top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p < 0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p > 0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p < 0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p < 0.05). Conclusion: The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment.
  • PublicationMetadata only
    The Effect of Curing Modes and Times of Third-Generation Led LCU on the Mechanical Properties of Nanocomposites
    (2022-09-01T00:00:00Z) OĞLAKƇI, Burcu; Ozlen, Rumeysa Hatice Enginler; DEMİRKOL, Metehan; ƖZDUMAN, ZƜMRƜT CEREN; KƜƇƜKYILDIRIM, Bedri Onur; DALKILIƇ, Evrim; OĞLAKƇI, BURCU; ƖZDUMAN, ZƜMRƜT CEREN; DALKILIƇ, EVRIM
    This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: supra-nanohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.
  • PublicationOpen Access
    Use of Artificial Neural Network in Determination of Shade, Light Curing Unit, and Composite Parameters- Effect on Bottom/Top Vickers Hardness Ratio of Composites
    (2018-01-01T00:00:00Z) Arjsu, Hacer Deniz; Dalkilic, EVRİM; Alkan, Fehime; Erol, Sebnem; Uctasli, Mine Betul; Cebi, Alican; DALKILIƇ, EVRIM
    Objective. To assess the influence of light emitting diode (LED) and quartz tungsten halogen (QTH) light curing unit (LCU) on the bottom/top (B/T) Vickers Hardness Number (VHN) ratio of different composites with different shades and determination of the most significant effect on B/T VHN ratio of composites by shade, light curing unit, and composite parameters using artificial neural network. Method. Three composite resin materials [Clearfil Majesty Esthetic (CME), Tetric N Ceram(TNC), and Tetric Evo Ceram (TEC)] in different shades (HO, A2, B2, Bleach L, Bleach M) were used. The composites were polymerized with three different LED LCUs (Elipar S10, Bluephase 20i, Valo) and halogen LCU (Hilux). Vickers hardness measurements were made at a load of 100 g for 10 sec on the top and bottom surfaces and B/T VHN ratio calculated. The data were statistically analyzed with three-way ANOVA and Tukey test at a significance level of 0.05. The obtained measurements and data were then fed to a neural network to establish the correlation between the inputs and outputs. Results. There were no significant differences between the B/T VHN ratio of LCUs for the HO and B shades of CME (p>0.05), but there were significant differences between the B/T VHN ratio of LCUs for shade A2 (p0.05). For TEC, there was no significant difference between the B/T VHN ratio of halogen and LED LCUs (p>0.05), but a significant difference was determined among the LED LCUs (p<0.05). The artificial neural network results showed that a combination of the curing light and composite parameter had the most significant effect on the B/T VHN ratio of composites. Shade has the lowest effect on the B/T VHN ratio of composites. Conclusion. The B/T VHN ratio values of different resin-based composite materials may vary depending on the light curing device. In addition, the artificial neural network results showed that the LCU and composite parameter had the most significant effect on the B/T VHN ratio of the composites. Shade has the lowest effect on the B/T VHN ratio of composites.
  • PublicationMetadata only
    Fracture Resistance and Failure Modes of Lithium Disilicate or Composite Endocrowns
    (2018-07-01T00:00:00Z) Altıer, Muhammed; Erol, Funda; Yıldırım, Gulhan; DALKILIƇ, EVRÄ°M; DALKILIƇ, EVRIM
    Purpose: The aim of this study was to determine the fracture strength of endocrowns made of lithium disilicate ceramic and two different indirect resin composites. Materials and Methods: Forty human mandibular molars were randomly separated into four groups (n = 10 in each group) -Group IN: control group, Group IPS: endocrowns made of lithium disilicate ceramic (IPS e. max CAD, IvoclarVivadent, Schaan, Liechtenstein); Group SL: Endocrowns made of Solidex microhybrid composite (Shofu, Ratingen, Germany); and Group GR: Endocrowns made of Grandia microhybrid composite (GC Europa, Leuven, Belgium). In all of the groups, dual-cure resin cement (Relyx Ultimate Clicker, 3M ESPE, St. Paul, MN, USA) was used to cement the endocrowns. All of the teeth were subjected to fracture by means of a universal testing machine (Instron), and compressive force was applied. The failure type and location after fracture were classified. The data were analyzed using one-way ANOVA, Tukey-s post hoc test, and Chi-square test (P 0.05). In Group SL, 80% of the specimens exhibited favorable fractures; also, 60% of the specimens exhibited favorable fracture in group GR, and only 10% of the specimens exhibited favorable fracture in group IPS. Conclusions: The lithium disilicate ceramic endocrowns exhibited higher fracture resistance than indirect composite groups. Both of the composite endocrowns showed more favorable failure than the lithium disilicate ceramic endocrowns.
  • PublicationOpen Access
    Can Fiber Application Affect the Fracture Strength of Endodontically Treated Teeth Restored with a Low Viscosity Bulk-Fill Composite?
    (2019-01-01) Dalkilic, Evrim Eliguzeloglu; Kazak, MAĞRUR; Hisarbeyli, DUYGU; Fildisi, MEHMET ALÄ°; Donmez, NAZMÄ°YE; Arisu, Hacer Deniz; DALKILIƇ, EVRIM; KAZAK, MAĞRUR; HÄ°SARBEYLÄ°, DUYGU; FÄ°LDİŞİ, MEHMET ALÄ°; DƖNMEZ, NAZMÄ°YE
    Objective: The aim of this study is to evaluate the effects of different fiber insertion techniques and thermomechanical aging on the fracture resistance of endodontically treated mandibular premolar teeth restored using bulk-fill composites. Materials and methods: Eighty human mandibular premolar teeth were randomly divided into eight groups: Group IN, Group BF, Group PRF1, Group PRF2, Group IN-TMA, Group BF-TMA, Group PRF1-TMA ,and Group PRF2-TMA. Group IN (intact) and Group IN-TMA (intact but subjected to thermomechanical aging) served as control groups. In the other six groups, endodontic treatment was performed and standardized mesio-occluso-distal (MOD) cavities were prepared. In BF, PRF1, and PRF2, the cavities were restored with bulk-fill composite only, bulk-fill/Ribbond, and bulk-fill/additional Ribbond, respectively. In BF-TMA, PRF1-TMA, and PRF2-TMA, the teeth were subjected to thermomechanical aging after the restorations. All of the teeth were fractured on the universal testing machine. Fracture surfaces were analyzed with a stereomicroscope. Results: Control groups showed significantly higher fracture strengths than tested groups (P<0.05). No statistically significant difference was observed among the tested groups (P>0.05). Most of the favorable fractures were seen in PRF1, PRF2, and PRF2-TMA. Most of the unfavorable fractures were seen in BF-TMA. Conclusions: Although fiber insertion with different techniques did not increase the fracture strength of teeth restored with bulk-fill composites, it increased the favorable fracture modes. Thermomechanical aging did not change the fracture strength of the groups.
  • PublicationMetadata only
    Influence of powdered dentin on the shear bond strength of dentin bonding systems
    (2012-09-01T00:00:00Z) Dalkilic, EVRİM; Genc, Ozgur; Ozcopur, Betul; Belli, Sema; Eskitascioglu, Gurcan; Oezcan, Mutlu; DALKILIƇ, EVRIM
    This study evaluated the effect of different amounts of dentin powder (DP) mixed in Clearfil SE Bond (CSB) or Single Bond (SB) on adhesion to dentin. Human third molars (n=96) were sectioned to expose the mid-coronal dentin and divided into eight experimental groups (n=12 per group), namely, Group 1: CSB, Group 2: CSB+1.5 mg DP, Group 3: CSB+3 mg DP, Group 4: CSB+4.5 mg DP, Group 5: SB, Group 6: SB+1.5 mg DP, Group 7: SB+3 mg DP, and Group 8: SB+4.5 mg DP. Filtek Z250 composite was bonded onto dentin, and all specimens were subjected to shear bond strength test at a crosshead speed of 1 mm/min. Highest bond strength was obtained in Groups 1, 2, and 3 (15.1, 13.5, and 16.4 MPa respectively; p>0.05) and the lowest in Groups 6, 7, and 8 (5.5, 5.6, 4 MPa; p>0.05). DP addition, regardless of amount, adversely affected the bond strength of SB. Bond strength of CSB was not affected when 1.5 or 3 rag of DP was added.
  • PublicationOpen Access
    The use of a liner under different bulk-fill resin composites: 3D GAP formation analysis by x-ray micro-computed tomography
    (2020-01-01T00:00:00Z) OĞLAKƇI, BURCU; Kazak, Magrur; DƖNMEZ, NAZMİYE; Dalkilic, Evrim; KƖYMEN, SAFİYE SELİN; OĞLAKƇI, BURCU; KAZAK, MAĞRUR; DƖNMEZ, NAZMİYE; DALKILIƇ, EVRIM; KƖYMEN, SAFİYE SELİN
    Gap formation of composite resin restorations is a serious shortcoming in clinical practice. Polymerization shrinkage stress exceeds the tooth-restoration bond strength, and it causes bacterial infiltration within gaps between cavity walls and the restorative material. Thus, an intermediate liner application with a low elastic modulus has been advised to minimize polymerization shrinkage as well as gap formation. Objective: The purpose of this in vitro study was to assess gap formation volume in premolars restored with different bulk-fill composites, with and without a resin-modified glass-ionomer cement (RMGIC) liner, using x-ray micro-computed tomography (micro-CT). Methodology: Sixty extracted human maxillary premolars were divided into six groups according to bucco-palatal dimensions (n=10). Standardized Class II mesio-occluso-distal cavities were prepared. G-Premio Bond (GC Corp., Japan) was applied in the selective-etch mode. Teeth were restored with high-viscosity (Filtek Bulk Fill, 3M ESPE, USA)-FB, sonic-activated (SonicFill 2, Kerr, USA)-SF and low viscosity (Estelite Bulk Fill Flow, Tokuyama, Japan)- EB bulk-fill composites, with and without a liner (Ionoseal, Voco GmbH, Germany)-L. The specimens were subjected to 10,000 thermocycles (5-55oC) and 50,000 simulated chewing cycles (100 N). Gap formation based on the volume of black spaces at the tooth-restoration interface was quantified in mm3 using micro-computed tomography (SkyScan, Belgium), and analyses were performed. Data were analyzed using repeated-measures ANOVA and the Bonferroni correction test (p < 0.05). Results: The gap volume of all tested bulk-fill composites demonstrated that Group SF (1.581Ā±0.773) had significantly higher values than Group EB (0.717Ā±0.679). Regarding the use of a liner, a significant reduction in gap formation volume was observed only in Group SFL (0.927Ā±0.630) compared with Group SF (1.581Ā±0.773). Conclusion: It can be concluded that different types of bulk-fill composite resins affected gap formation volume. Low-viscosity bulk-fill composites exhibited better adaptation to cavity walls and less gap formation than did sonic-activated bulk-fill composites. The use of an RMGIC liner produced a significant reduction in gap formation volume for sonic-activated bulk-fill composites.
  • PublicationMetadata only
    Two-year clinical evaluation of three adhesive systems in non-carious cervical lesions
    (2012-03-01T00:00:00Z) Dalkilic, EVRİM; Omurlu, Huma; DALKILIƇ, EVRIM
    Objectives: Adhesive systems are continuously being introduced to Dentistry, unfortunately often without sufficient clinical validation. The aim of this study was to evaluate the clinical performance of cervical restorations done with three different adhesive systems. Material and Methods: 158 non-carious cervical lesions of 23 patients were restored with a nanofilled composite resin (Filtek Supreme, 3M/ESPE) combined with Single Bond (3M/ESPE, group SI), Clearfil SE (Kuraray Medical Inc., group CL) and Xeno III (De Trey Dentsply, group XE). In groups SI-B, CL-B and XE-B, the outer surface of the sclerotic dentin was removed by roughening with a diamond bur before application of the respective adhesive systems. In groups CL-BP and XE-BP, after removal of the outer surface of the sclerotic dentin with the bur, the remaining dentin was etched with 37% phosphoric acid and the self-etch adhesive systems Clearfil SE and Xeno III were applied, respectively. Lesions were evaluated at baseline, and restorations after 3 months, 1 year and 2 years using modified USPHS criteria. Results: After 2 years, no significant difference was found between the retention rates of the groups (p>0.05). Although groups CL and SI showed significantly better marginal adaptation than group XE (p0.05). After 2 years no significant difference was observed among the marginal staining results of all groups (p>0.05). Conclusion: Although all adhesive systems showed similar retention rates, Clearfil SE and Single Bond showed better marginal adaptation than Xeno III after 2 years of follow-up.