• Home
  • About
  • Policies
  • Contact
    • English
    • Türkçe
  • English 
    • English
    • Türkçe
  • Login
Advanced Search
View Item 
  •   Home
  • Tüm Akademik Yayınlar
  • Yayınlar - Eserler
  • View Item
  •   Home
  • Tüm Akademik Yayınlar
  • Yayınlar - Eserler
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A Multicenter Experience of Thrombotic Microangiopathies in Turkey: The Turkish Hematology Research and Education Group (ThREG)-TMA01 Study

Thumbnail
Date
1.12.2016
Author
Tekgunduz, Emre; Yilmaz, Mehmet; Erkurt, Mehmet Ali; Kiki, Ilhami; Kaya, Ali Hakan; Kaynar, Leylagul; Alacacioglu, Inci; Cetin, Guven; Ozarslan, Ibrahim; Kuku, Irfan; Sincan, Gulden; Salim, Ozan; Namdaroglu, Sinem; Karakus, Abdullah; Karakus, Volkan; Pamuk, Gulsum Emel; Altuntas, Fevzi; Sari, Hakan Ismail; Ozet, Gulsum; Aydogdu, Ismet; Okan, Vahap; Kaya, Emin; Yildirim, Rahsan; Yildizhan, Esra; Ozgur, Gokhan; Ozcebe, Osman Ilhami; Payzin, Bahriye; Akpinar, Seval; Demirkan, Fatih
Advisor
Type
Meeting Abstract
Metadata
Show full item record
Abstract
In this study, we propose a novel cooling dehumidifying strategy, in which a condensing panel can be hydronically connected in series with the radiant cooling system to overcome condensation risk and improve indoor thermal comfort level. Based on the concept, the sensible heat-load is primarily covered by radiant cooling panels and some amount of latent heat and sensible heat can be treated by the condensing panel, while improving indoor thermal comfort level. Since, the surface temperature of the condensing panel is lower than the dew point temperature, while the radiant surface is higher for same supply water temperatures - condensation occurs only over the condensing plate. This paper evaluates the thermal comfort performance of the proposed novel condensing panel. For these aim, a new experimental chamber was developed. General thermal comfort level and the temperature, relative humidity ratio distribution in the tested room were evaluated for 10 different experimental cases. Multiple tests were conducted by varying surface temperature of the condensing panel and initial relative humidity ratios of air in the room. The results show that proposed simple solution can improve thermal comfort level, for the places where the latent heat loads are not considerable high, and reduce the condensation risk over the radiant cooling panels.
Subject
Radiant cooling; condensing panel; thermal comfort
URI
http://hdl.handle.net/20.500.12645/28542
https://doi.org/10.1182/blood.V128.22.4933.4933
Collections
  • WoS İndeksli Yayınlar Koleksiyonu
  • Yayınlar - Eserler

BEZMIALEM VAKIF UNIVERSITY

About us |Policies | Library | Contact us | Send Feedback | Sitemap | Admin

Bezmialem Vakıf Üniversitesi, Adnan Menderes Bulvarı Vatan Caddesi 34093 Fatih, İstanbul / TURKEY
Copyright © Bezmialem Vakıf Üniversitesi

Creative Commons Lisansı
Bezmialem Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

OpenAccess@BVU

Support by  UNIREPOS






sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageRightsAdvisorInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageRightsAdvisorInstitution Author

My Account

LoginRegister

BEZMIALEM VAKIF UNIVERSITY

About us |Policies | Library | Contact us | Send Feedback | Sitemap | Admin

Bezmialem Vakıf Üniversitesi, Adnan Menderes Bulvarı Vatan Caddesi 34093 Fatih, İstanbul / TURKEY
Copyright © Bezmialem Vakıf Üniversitesi

Creative Commons Lisansı
Bezmialem Institutional Repository, Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

OpenAccess@BVU

Support by  UNIREPOS