Publication:
Evaluation of inferior alveolar artery and its variations using three-dimensional rotational angiography

dc.contributor.authorSarikaya E. R.
dc.contributor.authorALAGÖZ E.
dc.contributor.authorSARICA İ.
dc.contributor.authorYILMAZ T. F.
dc.date.accessioned2025-11-24T21:36:22Z
dc.date.issued2025-09-23
dc.description.abstractPurpose This study aims to evaluate the morphological features and branching patterns of the inferior alveolar artery (IAA) in living individuals using three-dimensional rotational angiography (3D-RA) and to propose a novel radiological classification based on its shape and branching pattern. Methods A total of 101 hemifaces (53 right, 34 males/34 females) underwent 3D-RA imaging (slice thickness:0.10-0.20 mm). Morphological assessments of the maxillary artery (MA) and the IAA were performed on maximum intensity projection images. Statistical analysis used IBM SPSS Statistics 22.0 (p < 0.05). Results Mean diameters of the internal carotid artery (ICA), external carotid artery (ECA), and MA were 4.62 +/- 0.58 mm, 3.60 +/- 0.87 mm, and 2.35 +/- 0.41 mm, respectively. Females exhibited significantly smaller ICA, ECA, and MA diameters (p = 0.036, 0.001, 0.001), while IAA diameter (0.95 +/- 0.19 mm) showed no sex difference. The IAA originated predominantly from the MA (96%), rarely from the ECA (4%), or was not observed (1%). Duplicated IAAs were detected in two cases. Branching patterns included a single vessel (71%) or a shared trunk with the posterior deep temporal artery (29%), showing significant correlation with MA course (superficial/deep) (p < 0.05). IAA shapes were categorized as straight, curved, or looped, addressing a literature gap. Conclusions This is the first in vivo study to radiologically classify variations of the IAA using 3D-RA. The technique enables high-resolution visualization of submillimeter vessels, offering valuable anatomical insights for maxillofacial surgeries. Further studies are warranted to validate these findings and explore clinical correlations.
dc.identifier.citationSarikaya E. R., ALAGÖZ E., SARICA İ., YILMAZ T. F., "Evaluation of inferior alveolar artery and its variations using three-dimensional rotational angiography", INTERVENTIONAL NEURORADIOLOGY, 2025
dc.identifier.doi10.1177/15910199251380363
dc.identifier.issn1591-0199
dc.identifier.pubmed40986317
dc.identifier.urihttps://hdl.handle.net/20.500.12645/41387
dc.identifier.wosWOS:001577969500001
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDahili Tıp Bilimleri
dc.subjectNöroloji
dc.subjectNükleer Tıp
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectInternal Medicine Sciences
dc.subjectNeurology
dc.subjectNuclear medicine
dc.subjectHealth Sciences
dc.subjectKlinik Nöroloji
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (Med)
dc.subjectRadyoloji Nükleer Tıp ve Medikal Görüntüleme
dc.subjectClinical Neurology
dc.subjectClinical Medicine
dc.subjectClinical Medicine (Med)
dc.subjectRadiology Nuclear Medicine & Medical Imaging
dc.subjectRadyoloji ve Ultrason Teknolojisi
dc.subjectRadyoloji, Nükleer Tıp ve Görüntüleme
dc.subjectNöroloji (klinik)
dc.subjectYaşam Bilimleri
dc.subjectRadiological and Ultrasound Technology
dc.subjectRadiology, Nuclear Medicine and Imaging
dc.subjectNeurology (clinical)
dc.subjectLife Sciences
dc.titleEvaluation of inferior alveolar artery and its variations using three-dimensional rotational angiography
dc.typearticle
dspace.entity.typePublication
local.avesis.id0603c101-b349-47ad-9bac-8668ade7d9a6

Files