Publication:
Temperature rise on external root surface during 810- and 970-nm diode laser application in endodontic treatments

dc.contributor.authorArslan D.
dc.contributor.authorKAPLAN F.
dc.contributor.authorStoicefidis K.
dc.contributor.authorDalkılıç E. M.
dc.contributor.institutionauthorKAPLAN, FATMA
dc.date.accessioned2024-02-21T21:50:14Z
dc.date.available2024-02-21T21:50:14Z
dc.date.issued2024-12-01
dc.description.abstractPurpose: The aim of this study was to evaluate the temperature rise on the external root surface during 810- and 970-nm diode laser application. Methods: Thirty-six single-rooted mandibular premolar teeth were employed. All of the root canals were prepared at 1 mm short of the apical foramen; after working length determination, each root canal was prepared using ProTaper Universal instruments. The roots were randomly divided into 2 groups of 18 specimens in each. A 810-nm diode laser in group 1 and 970-nm diode laser in group 2 were used with continuous mode and 1.5 W parameters. The temperature elevations were measured with an infrared thermographic camera during 810- and 970-nm diode laser irradiation. Data were analyzed statistically using Kruskal–Wallis and Tukey’s tests. Results: No significant difference was obtained among the 810- and 970-nm diode laser groups according to the temperature changes (P > 0.05). Temperature rise values in all the teeth were detected below 10 °C. Conclusion: Within the limitations of this in vitro study, the 810- and 970-nm diode laser irradiation is a safe supported treatment option when considering the temperature elevation on the external root surface and these lasers can be safely used for endodontic treatments at the investigated parameters. The peak temperature was below the critical value.
dc.identifier.citationArslan D., KAPLAN F., Stoicefidis K., Dalkılıç E. M., "Temperature rise on external root surface during 810- and 970-nm diode laser application in endodontic treatments", Lasers in Dental Science, cilt.8, sa.1, 2024
dc.identifier.doi10.1007/s41547-024-00213-9
dc.identifier.issn2367-2587
dc.identifier.issue1
dc.identifier.scopus85183424630
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85183424630&origin=inward
dc.identifier.urihttps://hdl.handle.net/20.500.12645/39105
dc.identifier.volume8
dc.relation.ispartofLasers in Dental Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectDentistry
dc.subjectHealth Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectDENTISTRY, ORAL SURGERY & MEDICINE
dc.subjectOrtodonti
dc.subjectAğız Cerrahisi
dc.subjectDiş Hekimliği (çeşitli)
dc.subjectPeriodontoloji
dc.subjectOrthodontics
dc.subjectOral Surgery
dc.subjectDentistry (miscellaneous)
dc.subjectPeriodontics
dc.subjectDiode laser
dc.subjectInfrared thermographic camera
dc.subjectTemperature
dc.subjectWavelength
dc.titleTemperature rise on external root surface during 810- and 970-nm diode laser application in endodontic treatments
dc.typeArticle
dspace.entity.typePublication
local.avesis.id1d666ee9-9dc2-40f1-a7f8-15f1a456cf4d
local.indexed.atScopus
relation.isAuthorOfPublication75a99fd5-a9e2-4ee1-8ad2-1a76258884bf
relation.isAuthorOfPublication.latestForDiscovery75a99fd5-a9e2-4ee1-8ad2-1a76258884bf

Files