Publication: Effects of Water Flow Rate on Shear Bond Strength of Orthodontic Bracket Bonded to Enamel Surface After Er:YAG Laser Ablation
dc.contributor.author | Topcuoglu, Tolga | |
dc.contributor.author | Oksayan, Ridvan | |
dc.contributor.author | Ademci, K. Ebru | |
dc.contributor.author | GÖYMEN, MERVE | |
dc.contributor.author | Usumez, Serdar | |
dc.contributor.author | Usumez, Aslihan | |
dc.date.accessioned | 2020-10-22T20:21:52Z | |
dc.date.available | 2020-10-22T20:21:52Z | |
dc.date.issued | 2013-10-01T00:00:00Z | |
dc.description.abstract | Objective: The aim of present study was to evaluate the effect of water flow rate on enamel surface roughness and shear bond strength (SBS) of orthodontic brackets after Er:YAG laser ablation. Background data: It is well known that external water supply is a fundamental requirement for Er:YAG laser efficiency on dental hard tissues. However, there is no consensus considering the water flow rate used during Er:YAG laser ablation. Methods: Eighty sound human upper premolar teeth were used in the present study. Seventy-six teeth were assigned into four groups according to surface treatments. The 37% phosphoric acid-etched group served as the control. Er:YAG laser irradiation was performed in three subgroups with water flow rates of 25, 36, and 48mL/min, respectively. All specimens were subjected to a SBS test. One specimen from each different surface treatment modality was examined by scanning electron microscopy. Kruskal-Wallis test was used to compare the SBS value of each group. Results: Although the control group had the highest SBS value, statistically no significant differences were found among groups. Conclusions: Er:YAG laser application with a water flow rate of 48mL/min produced better enamel surface alterations without any thermal damage to yield higher SBS values. | |
dc.identifier.citation | Topcuoglu T., Oksayan R., Ademci K. E. , GÖYMEN M., Usumez S., Usumez A., -Effects of Water Flow Rate on Shear Bond Strength of Orthodontic Bracket Bonded to Enamel Surface After Er:YAG Laser Ablation-, PHOTOMEDICINE AND LASER SURGERY, cilt.31, ss.486-491, 2013 | |
dc.identifier.doi | 10.1089/pho.2013.3564 | |
dc.identifier.scopus | 84885404062 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/24714 | |
dc.identifier.wos | WOS:000325361100005 | |
dc.title | Effects of Water Flow Rate on Shear Bond Strength of Orthodontic Bracket Bonded to Enamel Surface After Er:YAG Laser Ablation | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | de9eb1d0-a416-4d9e-8982-6d82fdac5a0e | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.goal | 06 - Temiz Su ve Sanitasyon | |
local.publication.isinternational | 1 | |
relation.isGoalOfPublication | acbed29c-2d3d-448c-8852-f8e28f69d294 | |
relation.isGoalOfPublication.latestForDiscovery | acbed29c-2d3d-448c-8852-f8e28f69d294 |