Publication:
Dosimetric Evaluation of Total Body Irradiations with Helical Tomotherapy: Phantom Study

dc.contributor.authorgökçe uçar alveroğlu
dc.date.accessioned2026-11-09T19:20:13Z
dc.date.issued2022-01-01
dc.description.abstractOBJECTIVE In total body irradiations (TBI), it becomes hard getting homogenous dose distribution due to inhomogeneous body shape and tissue density variations. The main goal of the radiotherapy is saving critic organs while achieving a homogeneous dose distribution at target volume. Tomotherapy is a new and one of the most effective technologies used for TBIs. In this study, it was aimed to investigate TBI planned target volume coverage and organ doses using helical tomotherapy. METHODS To simulate rando phantom geometrically, arms and legs created by rice are added to rando phantom and were immobilized by a vacuum bed. The computer tomography images of the lower and upper region of the phantom with a slice thickness of 3 mm were acquired. Thermoluminescent dosimeters (TLDs) were placed entrance-exit, midpoint doses of lens, lungs, and kidneys onto a rando phantom. The treatment plans were prepared and irradiated with helical tomotherapy technique. Results of the measurements and treatment planning system (TPS) doses were compared. All procedures were repeated 3 times and averaged. TPS and TLD doses were evaluated by Wilcoxon test. RESULTS In the plans prepared with the TPS, a homogeneous dose distribution was obtained with a homogeneity index of 0.16 for the upper body and 0.04 for the lower body. When the calculated critical organ doses were compared with the measured organ doses, there was no statistically significant difference between them. CONCLUSION It was seen that saving critical organs and achieving desired dose distribution are possible without blocks in tomotherapy. Doses calculated from TPS and measured by TLD matched.en
dc.identifier.doi10.5505/tjo.2022.3722
dc.identifier.issn1300-7467
dc.identifier.scopus2-s2.0-85149538600
dc.identifier.trdizin1177105
dc.identifier.urihttps://doi.org/10.5505/tjo.2022.3722
dc.identifier.urihttps://hdl.handle.net/20.500.12645/42833
dc.identifier.wos000903517000001
dc.language.isoen
dc.publisherLookUs Bilisim A.S.
dc.relation.ispartofTurkish Journal of Oncology
dc.rightsopenAccess
dc.sourceOpenAire
dc.titleDosimetric Evaluation of Total Body Irradiations with Helical Tomotherapy: Phantom Studyen
dc.typeArticle
dspace.entity.typePublication
local.indexed.atWOS
local.indexed.atScopus
local.indexed.atTRDizin

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10_5505_tjo_2022_3722.pdf
Size:
1,007.79 KB
Format:
Adobe Portable Document Format