Comparison of Reliability of 3 Resonance Frequency Devices: An In Vitro

dc.contributor.authorDİKER, BURCU
dc.contributor.authorDİKER, NURETTİN
dc.contributor.authorTak, Onjen
dc.contributor.institutionauthorDİKER, BURCU
dc.contributor.institutionauthorDİKER, NURETTİN
dc.date.accessioned2022-05-10T20:59:56Z
dc.date.available2022-05-10T20:59:56Z
dc.date.issued2022-02-01T00:00:00Z
dc.description.abstractThe purpose of the present study was to investigate the intraobserver and interobserver reliability of 3 resonance frequency analysis (RFA) devices and to compare the implant stability quotient (ISQ) values according to implant macro design and diameter in 2 different bone densities. A total of 64 implants (Neoss ProActive; Neoss; Harrogate, UK) of varying diameters (3.5 and 4.0 mm) and implant macro design (tapered and straight) were placed in 2 artificial bone blocks (the density of type 2 and 3). The implant primary stability was measured using Osstell IDx (Osstell; Go center dot teborg, Sweden), Osstell Beacon and Penguin RFA (Integration Diagnostics; Go center dot teborg, Sweden). The ISQ value of each implant was measured by 2 observers and recorded 5 times in 2 directions. The intraobserver and interobserver reliability of RFA devices were evaluated. In addition to that, mean ISQ values were calculated for each RFA device to evaluate the effect of implant diameter, implant macro design, and bone density on ISQ values. ISQ values were significantly higher for implants placed within the type 2 bone than for the type 3 bone. The 4.0-mm diameter implants presented higher ISQ values than 3.5-mm diameter implants. The intraclass correlation coefficient (ICC) values for intraobserver reliability were above 0.85 for each observer and the ICC values for interobserver reliability were 0.94, 0.93, and 0.98 for Osstell IDx, Osstell Beacon, and Penguin RFA, respectively. Although there was excellent interobserver reliability with 3 RFA devices, the intraobserver reliability of Osstell Beacon and Penguin RFA were slightly better than Osstell IDx. Bone density and implant diameter were parameters affecting the primary stability of implants.
dc.identifier.citationDİKER B., DİKER N., Tak O., -Comparison of Reliability of 3 Resonance Frequency Devices: An In Vitro-, JOURNAL OF ORAL IMPLANTOLOGY, cilt.48, sa.1, ss.9-14, 2022
dc.identifier.doi10.1563/aaid-joi-d-20-00139
dc.identifier.pubmed33760051
dc.identifier.scopus85128247426
dc.identifier.urihttp://hdl.handle.net/20.500.12645/30589
dc.identifier.wosWOS:000786304200001
dc.titleComparison of Reliability of 3 Resonance Frequency Devices: An In Vitro
dc.typeArticle
dspace.entity.typePublication
local.avesis.id6853f472-a678-4551-8775-d2624d6ebd87
local.indexed.atPubMed
local.indexed.atWOS
local.indexed.atScopus
local.publication.isinternational1
relation.isAuthorOfPublication8541023a-5e1a-40cd-89e0-0807dbb03a5b
relation.isAuthorOfPublicationaad04544-dd5e-45d4-a15d-24365e416f6e
relation.isAuthorOfPublication.latestForDiscovery8541023a-5e1a-40cd-89e0-0807dbb03a5b

Files