Publication:
Assessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcification

dc.contributor.authorAcikgoz, Nusret
dc.contributor.authorPEKDEMİR, HASAN
dc.contributor.authorCANSEL, MEHMET
dc.contributor.authorYagmur, Julide
dc.contributor.authorERMİŞ, NECİP
dc.contributor.authorKurtoglu, Ertugrul
dc.contributor.authorTasolar, Hakan
dc.contributor.authorAtas, Halil
dc.contributor.authorÖZDEMİR, Ramazan
dc.contributor.institutionauthorAÇIKGÖZ, NUSRET
dc.contributor.institutionauthorÖZDEMİR, RAMAZAN
dc.date.accessioned2021-02-01T20:59:42Z
dc.date.available2021-02-01T20:59:42Z
dc.date.issued2010-07-01T00:00:00Z
dc.description.abstractThe aim of our study was to investigate atrial conduction time in patients with mitral annulus calcification (MAC) using P-wave dispersion (PWD) and electromechanical coupling measured with the surface electrocardiogram and the tissue Doppler echocardiography. Fifty-nine patients with MAC and 43 control subjects underwent resting the surface electrocardiogram and tissue Doppler echocardiography. The difference between the maximum (Pmax) and minimum P-wave durations was calculated and defined as PWD. Interatrial and intraatrial electromechanical delays were measured with tissue Doppler echocardiography. Both Pmax and PWD were higher in patients with MAC compared with controls (111.4 +/- 15.8 vs 97.3 +/- 18.8 milliseconds; P < .0001 and 46.4 +/- 14.6 vs 31.4 +/- 13.1 milliseconds; P < .0001, respectively). Both interatial and intraatrial conduction time were also delayed in patients with MAC compared with controls (29.8 +/- 13.3 vs 17.6 +/- 12.5 milliseconds; P < .0001; 9.4 +/- 5.1 vs 6.8 +/- 4.0 milliseconds; P < .008, respectively). Left atrial (LA) diameter was significantly higher in patients with MAC compared with controls (35.4 +/- 5.0 mm vs 32.3 +/- 4.2 mm; P < .001). The LA diameter correlated significantly with both interatrial conduction times and PWD (r = 0.56; P < .0001 and r = 0.47; P < .0001, respectively). There is a delay in both intraatrial and interatrial electromechanical coupling intervals in patients with MAC. (C) 2010 Elsevier Inc. All rights reserved.
dc.identifier.citationPEKDEMİR H., CANSEL M., Yagmur J., Acikgoz N., ERMİŞ N., Kurtoglu E., Tasolar H., Atas H., ÖZDEMİR R., -Assessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcification-, JOURNAL OF ELECTROCARDIOLOGY, cilt.43, ss.339-343, 2010
dc.identifier.doi10.1016/j.jelectrocard.2010.02.013
dc.identifier.scopus77953606264
dc.identifier.urihttp://hdl.handle.net/20.500.12645/28252
dc.identifier.wosWOS:000279483000013
dc.titleAssessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcification
dc.typeArticle
dspace.entity.typePublication
local.avesis.id86445900-ae21-47c2-8dec-be48dd6fce5c
local.indexed.atWOS
local.indexed.atScopus
local.publication.isinternational1
relation.isAuthorOfPublication3c6f1693-fd8c-43c4-8f55-e1388d929a53
relation.isAuthorOfPublication6384fc88-e60f-4402-bacf-1f1b2120fb58
relation.isAuthorOfPublication.latestForDiscovery3c6f1693-fd8c-43c4-8f55-e1388d929a53

Files

Collections