Publication:
Wavelength selection in measuring red blood cell aggregation based on light transmittance

dc.contributor.authorUyuklu, MEHMET
dc.contributor.authorCANPOLAT, MURAT
dc.contributor.authorMeiselman, Herbert J.
dc.contributor.authorBaskurt, Oguz K.
dc.contributor.institutionauthorÜYÜKLÜ, MEHMET
dc.date.accessioned2020-10-29T20:30:42Z
dc.date.available2020-10-29T20:30:42Z
dc.date.issued2011-11-01T00:00:00Z
dc.description.abstractThe reversible aggregation of red blood cells (RBC) is of current basic science and clinical interest. Using a flow channel and light transmittance (LT) through RBC suspensions, we have examined the effects of wavelength (500 to 900 nm) on the static and dynamic aspects of RBC aggregation for normal blood and suspensions with reduced or enhanced aggregation; the effects of oxygenation were also explored. Salient observations include: 1. significant effects of wavelength on aggregation parameters reflecting the extent of aggregation (i.e., number of RBC per aggregate); 2. no significant effects of wavelength on parameters reflecting the time course of RBC aggregation; 3. a prominent influence of hemoglobin oxygen saturation on both extent and time-course related aggregation parameters measured at wavelengths less than 700 nm, but only on the time-course at 800 nm; and 4. the power of parameters in detecting a given alteration of RBC aggregation is affected by wavelength, in general being greater at higher wavelengths. It is recommended that light sources with wavelengths around 800 nm be used in instruments for measuring RBC aggregation via LT. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3652712]
dc.identifier.citationUyuklu M., CANPOLAT M., Meiselman H. J. , Baskurt O. K. , -Wavelength selection in measuring red blood cell aggregation based on light transmittance-, JOURNAL OF BIOMEDICAL OPTICS, cilt.16, 2011
dc.identifier.doi10.1117/1.3652712
dc.identifier.scopus80655143450
dc.identifier.urihttp://hdl.handle.net/20.500.12645/26083
dc.identifier.wosWOS:000298546500040
dc.titleWavelength selection in measuring red blood cell aggregation based on light transmittance
dc.typeArticle
dspace.entity.typePublication
local.avesis.id6db741a5-3a42-4cd2-ba78-191000b357f9
local.indexed.atWOS
local.indexed.atScopus
local.publication.isinternational1
relation.isAuthorOfPublicationbc1199b5-be6a-43cc-9b25-7e47066119cc
relation.isAuthorOfPublication.latestForDiscoverybc1199b5-be6a-43cc-9b25-7e47066119cc

Files

Collections