Publication: A New Specific Device in Transcatheter Prosthetic Paravalvular Leak Closure: A Prospective Two-Center Trial
dc.contributor.author | Yildirim, Aydin; Goktekin, Omer; Gorgulu, Sevket; Norgaz, Tugrul; Akkaya, Emre; Aydin, Unal; Aksu, Hale Unal; Bakir, Ihsan | |
dc.date.accessioned | 2021-03-14T19:17:52Z | |
dc.date.available | 2021-03-14T19:17:52Z | |
dc.date.issued | 1.10.2016 | |
dc.description.abstract | BackgroundThis study sought to compare various outcomes among a new specifically designed transcatheter paravalvular leak closure (TPVLC) device and the devices that are being utilized off-label. MethodsBetween April 2012 and January 2015, in a prospective two-center study, 52 patients who needed surgical reintervention due to a hemodynamically significant prosthetic paravalvular leak were studied. This study population was divided into two groups. Group I was composed of 32 patients who underwent paravalvular leak (PVL) closure with the currently available devices that are being utilized off-label, while group II consisted of 20 patients who were treated with the new specifically designed Occlutech PVL device. ResultsDemographic and clinical variables indicated a higher rate of atrial fibrillation (P=0.027) and chronic obstructive airway disease (P=0.009) in group II. The apical approach was the most commonly used intervention route used for group II (P=0.019). The procedural success rate was 100% (29 of 29 leaks) in group II while the rate was 92% (39 of 42 leaks) in group I. However, more secondary events were observed in group I, but they did not reach statistical significance (8 vs. 1, P=0.064). ConclusionsWith its high procedural success rate and encouraging outcome results, the Occlutech device seems to satisfy the expectations of a specifically designed PVL closure device. (c) 2016 Wiley Periodicals, Inc. | |
dc.identifier.doi | 10.1002/ccd.26439 | |
dc.identifier.eissn | 1522-726X | |
dc.identifier.isbn | 978-1-5386-4478-2 | |
dc.identifier.issn | 1522-1946 | |
dc.identifier.pubmed | 26909784 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/28541 | |
dc.identifier.wos | WOS:000386800000026 | |
dc.language.iso | en | |
dc.subject | specific device; prosthetic valve; paravalvular leak closure | |
dc.title | A New Specific Device in Transcatheter Prosthetic Paravalvular Leak Closure: A Prospective Two-Center Trial | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.indexed.at | PubMed | |
local.indexed.at | WOS |