Publication:
Comparison of atrial electromechanical coupling interval and P-wave dispersion in non-dipper versus dipper hypertensive subjects

dc.contributor.authorAcikgoz, Nusret
dc.contributor.authorERMİŞ, NECİP
dc.contributor.authorCuglan, Bilal
dc.contributor.authorCANSEL, MEHMET
dc.contributor.authorYagmur, Julide
dc.contributor.authorTasolar, Hakan
dc.contributor.authorBarutcu, Irfan
dc.contributor.authorPEKDEMİR, HASAN
dc.contributor.authorÖZDEMİR, Ramazan
dc.contributor.institutionauthorAÇIKGÖZ, NUSRET
dc.contributor.institutionauthorÖZDEMİR, RAMAZAN
dc.date.accessioned2021-02-01T20:59:24Z
dc.date.available2021-02-01T20:59:24Z
dc.date.issued2011-02-01T00:00:00Z
dc.description.abstractBackground. The lack of nocturnal BP fall less than 10% of the daytime, called non-dipper hypertension, is associated with increased cardiovascular morbidity and mortality. The aim of our study was to investigate atrial conduction time in patients with non-dipper hypertension using electromechanical coupling interval and P-wave dispersion (PWD), measured with the surface electrocardiogram and tissue Doppler echocardiographic imaging (TDI). Methods. Age-and sex-matched 43 dipper hypertensive patients (19 male, 24 female, mean age: 53.9 +/- 10.5 years), 40 non-dipper patients (18 male, 22 female, mean age 54.3 +/- 9.6 years) and 46 healthy subjects (22 male, 24 female, mean age: 52.8 +/- 9.6 years) were included in the study. The difference between the maximum and minimum P-wave durations was calculated and defined as PWD. Atrial electromechanical coupling (PA), inter-atrial and intra-atrial electromechanical delays were measured with TDI. Results. PWD was significantly higher in patients with non-dippers compared with dippers (p < 0.02) and controls (p < 0.001). The inter-atrial conduction time was delayed in non-dippers compared with dippers (p < 0.01) and controls (p < 0.001). There was a positive correlation between left atrial (LA) diameter and inter-atrial conduction times (r = 0.46, p < 0.001). LA diameter was also correlated with PWD (r = 0.44, p < 0.001). Conclusion. The patients with non-dipper hypertension have higher P-wave duration, PWD and delayed inter-atrial electromechanical coupling intervals compared with those of dippers and controls. This indicates that these subjects may be more prone to atrial rhythm disturbances.
dc.identifier.citationERMİŞ N., Acikgoz N., Cuglan B., CANSEL M., Yagmur J., Tasolar H., Barutcu I., PEKDEMİR H., ÖZDEMİR R., -Comparison of atrial electromechanical coupling interval and P-wave dispersion in non-dipper versus dipper hypertensive subjects-, BLOOD PRESSURE, cilt.20, ss.60-66, 2011
dc.identifier.doi10.3109/08037051.2010.532302
dc.identifier.scopus79251495492
dc.identifier.urihttp://hdl.handle.net/20.500.12645/28233
dc.identifier.wosWOS:000286618300011
dc.titleComparison of atrial electromechanical coupling interval and P-wave dispersion in non-dipper versus dipper hypertensive subjects
dc.typeArticle
dspace.entity.typePublication
local.avesis.id3f125fb9-a5aa-4dd1-b743-b7d94ab4a80d
local.indexed.atWOS
local.indexed.atScopus
local.publication.isinternational1
relation.isAuthorOfPublication3c6f1693-fd8c-43c4-8f55-e1388d929a53
relation.isAuthorOfPublication6384fc88-e60f-4402-bacf-1f1b2120fb58
relation.isAuthorOfPublication.latestForDiscovery6384fc88-e60f-4402-bacf-1f1b2120fb58

Files

Collections