Publication: Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study
dc.contributor.author | Gensicke, Henrik | |
dc.contributor.author | Evans, James W. | |
dc.contributor.author | Al Ajlan, Fahad S. | |
dc.contributor.author | Dowlatshahi, Dar | |
dc.contributor.author | Najm, Mohamed | |
dc.contributor.author | Calleja, Ana L. | |
dc.contributor.author | Puig, Josep | |
dc.contributor.institutionauthor | ASİL, TALIP | |
dc.date.accessioned | 2020-10-22T20:39:42Z | |
dc.date.available | 2020-10-22T20:39:42Z | |
dc.description.abstract | Purpose To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase. Methods Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (= 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax <= 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8). Conclusion Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers. | |
dc.identifier.citation | Gensicke H., Evans J. W. , Al Ajlan F. S. , Dowlatshahi D., Najm M., Calleja A. L. , Puig J., Sohn S., Ahn S. H. , Poppe A. Y. , et al., -Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study-, NEURORADIOLOGY, cilt.62, ss.301-306, 2020 | |
dc.identifier.doi | 10.1007/s00234-019-02320-y | |
dc.identifier.pubmed | 31713667 | |
dc.identifier.scopus | 85075197282 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/24841 | |
dc.identifier.wos | WOS:000495942400003 | |
dc.title | Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | ebcf70b6-d351-4238-af43-97719b63156c | |
local.indexed.at | PubMed | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 | |
relation.isAuthorOfPublication | d6d2b335-cf30-4de8-b2c6-9d158f661759 | |
relation.isAuthorOfPublication.latestForDiscovery | d6d2b335-cf30-4de8-b2c6-9d158f661759 |