Publication: Evaluation of Debris Extruded Apically during the Removal of Root Canal Filling Material Using ProTaper, D-RaCe, and R-Endo Rotary Nickel-Titanium Retreatment Instruments and Hand Files
dc.contributor.author | TOPÇUOĞLU, Hüseyin Sinan | |
dc.contributor.author | Akti, Abmet | |
dc.contributor.author | Tuncay, Oznur | |
dc.contributor.author | Dincer, Asiye Nur | |
dc.contributor.author | Duzgun, Salib | |
dc.contributor.author | Topcuoglu, Gamze | |
dc.contributor.institutionauthor | DİNÇER, ASİYE NUR | |
dc.date.accessioned | 2020-10-29T21:35:32Z | |
dc.date.available | 2020-10-29T21:35:32Z | |
dc.date.issued | 2014-12-01T00:00:00Z | |
dc.description.abstract | Introduction: The aim of this study was to evaluate the amount of debris extruded apically during the removal of root canal filling material using ProTaper (Dentsply Maillefer, Ballaigues, Switzerland), D-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and R-Endo (Micro-Mega, Besancon, France) nickel-titanium (NiTi) rotary retreatment instruments and hand files. Methods: Sixty extracted single-rooted mandibular premolar teeth were prepared with K-files and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). The teeth were then randomly assigned to 4 groups (n = 15 for each group) for retreatment. The removal of canal filling material was performed as follows: hand files, ProTaper, D-RaCe, and R-Endo retreatment instruments. Debris extruded apically during the removal of canal filling material was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70 degrees C for 5 days. The weight of the dry extruded debris was established by subtracting the preretreatment and postretreatment weight of the Eppendorf tubes for each group. The data obtained were analyzed using 1-way analysis of variance and Tukey post hoc tests. Results: All retreatment techniques caused the apical extrusion of debris. Hand files produced significantly more debris when compared with ProTaper, D-RaCe, and R-Endo rotary systems (P .05). Conclusions: The findings showed that during the removal of root canal filling material, rotary NiTi retreatment instruments used in this study caused less apical extrusion of debris compared with hand files. | |
dc.identifier.citation | TOPÇUOĞLU H. S. , Akti A., Tuncay O., Dincer A. N. , Duzgun S., Topcuoglu G., -Evaluation of Debris Extruded Apically during the Removal of Root Canal Filling Material Using ProTaper, D-RaCe, and R-Endo Rotary Nickel-Titanium Retreatment Instruments and Hand Files-, JOURNAL OF ENDODONTICS, cilt.40, ss.2066-2069, 2014 | |
dc.identifier.doi | 10.1016/j.joen.2014.09.004 | |
dc.identifier.scopus | 84927596173 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/26337 | |
dc.identifier.wos | WOS:000346553200033 | |
dc.title | Evaluation of Debris Extruded Apically during the Removal of Root Canal Filling Material Using ProTaper, D-RaCe, and R-Endo Rotary Nickel-Titanium Retreatment Instruments and Hand Files | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | 91ae411b-acae-4f7a-889c-85ac665772df | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 | |
relation.isAuthorOfPublication | 280079fc-4c47-445a-94a7-4224ec2adeb5 | |
relation.isAuthorOfPublication.latestForDiscovery | 280079fc-4c47-445a-94a7-4224ec2adeb5 |