Publication:
Factors Affecting Attachment Loss in Clear Aligner Treatment: A Prospective Clinical Study

dc.contributor.authorŞahin Ş.
dc.contributor.authorÜnsal H.
dc.contributor.authorKurt G.
dc.date.accessioned2026-10-13T06:18:01Z
dc.date.issued2026-07-01
dc.description.abstractObjective: This study aimed to evaluate the incidence of composite attachment loss in patients undergoing clear aligner treatment and to identify patient-, tooth-, and treatment- related factors associated with attachment debonding. Methods: Twenty-one patients (17 females, 4 males; mean age 23.86±8.21 years) receiving clear aligner therapy were included. Attachments were bonded according to the manufacturer’s protocol using high-viscosity composite. Patients were followed for 6 months and attachment loss was recorded at routine appointments. Statistical analyses were performed using Fisher’s exact test, Yates’ correction, and Pearson chi-square test, with p≤0.05 considered significant. Results: Among 427 attachments, 21 were lost. Attachment loss was significantly associated with attachment type (conventional vs. optimized, p=0.009) and tooth type (p=0.0005), with the highest loss rate observed in molars. No significant associations were observed between attachment loss and attachment size, dental arch, patient sex, chewing habits, daily aligner wear time, aligner removal frequency, or removal direction. Conclusion: Attachment loss in clear aligner treatment was associated with attachment type and tooth type. Optimized attachments showed improved retention, while molars exhibited the highest attachment loss rate.en
dc.identifier.citationŞahin Ş., Ünsal H., Kurt G., "Factors Affecting Attachment Loss in Clear Aligner Treatment: A Prospective Clinical Study", BEZMIALEM SCIENCE, cilt.14, sa.3, ss.294-300, 2026
dc.identifier.doi10.14235/bas.galenos.2026.64497
dc.identifier.endpage300
dc.identifier.issn2148-2373
dc.identifier.issue3
dc.identifier.startpage294
dc.identifier.trdizin1448989
dc.identifier.urihttps://doi.org/10.14235/bas.galenos.2026.64497
dc.identifier.urihttps://hdl.handle.net/20.500.12645/42329
dc.identifier.volume14
dc.relation.ispartofBEZMIALEM SCIENCE
dc.rightsopenAccess
dc.subjectSağlık bilimleri
dc.subjectHealth sciences
dc.subjectKlinik tıp (med)
dc.subjectClinical medicine (med)
dc.titleFactors Affecting Attachment Loss in Clear Aligner Treatment: A Prospective Clinical Study
dc.typearticle
dspace.entity.typePublication
local.avesis.idebfd0fd2-53e5-4302-b0ac-0a7e5faf4f45
local.indexed.atTRDizin

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10_14235_bas_galenos_2026_64497.pdf
Size:
491.19 KB
Format:
Adobe Portable Document Format