Publication:
Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study

dc.contributor.authorÖZDUMAN, ZÜMRÜT CEREN
dc.contributor.authorKazak, Magrur
dc.contributor.authorFİLDİŞİ, MEHMET ALİ
dc.contributor.authorÖZLEN, RÜMEYSA HATİCE
dc.contributor.authorDALKILIÇ, Evrim
dc.contributor.authorDÖNMEZ, NAZMİYE
dc.contributor.institutionauthorÖZDUMAN, ZÜMRÜT CEREN
dc.contributor.institutionauthorFİLDİŞİ, MEHMET ALİ
dc.contributor.institutionauthorÖZLEN, RÜMEYSA HATİCE
dc.contributor.institutionauthorDALKILIÇ, EVRIM
dc.contributor.institutionauthorDÖNMEZ, NAZMİYE
dc.date.accessioned2020-01-13T20:59:39Z
dc.date.available2020-01-13T20:59:39Z
dc.date.issued2019-01-01T00:00:00Z
dc.description.abstractObjective: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. Materials-methods: For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n = 5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n = 12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey's HSD test. The data from the top surface of specimens' microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-Whitney U tests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p < 0.05). Results: The B/T microhardness ratio results revealed no significant differences between groups (p > 0.05). Comparing the microhardness values of the composites' top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p < 0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p > 0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p < 0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p < 0.05). Conclusion: The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment.en
dc.identifier.citationÖZDUMAN Z. C. , Kazak M., FİLDİŞİ M. A. , ÖZLEN R. H. , DALKILIÇ E., DÖNMEZ N., -Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study-, Scanning, cilt.2019, 2019
dc.identifier.doi10.1155/2019/2307305
dc.identifier.pubmed31281561
dc.identifier.scopus85069289556
dc.identifier.urihttps://openaccess.bezmialem.edu.tr/handle/20.500.12645/12290
dc.identifier.wosWOS:000471944700001
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.titleEffect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study
dc.typeArticle
dspace.entity.typePublication
local.avesis.iddca51a7b-6e9c-47f0-a499-1292ae854416
local.publication.isinternational1
relation.isAuthorOfPublication8973577b-f26e-47eb-bd38-0fb640108171
relation.isAuthorOfPublication21a4fc1c-d033-41b0-b4cf-b55dbf5fe930
relation.isAuthorOfPublication3b626b33-6c49-4040-bf87-c21dc9b8efb7
relation.isAuthorOfPublication05592be3-8323-4273-bfff-96d4c4775aa8
relation.isAuthorOfPublication290534fc-5729-4123-86c9-b3d70bded178
relation.isAuthorOfPublication.latestForDiscovery21a4fc1c-d033-41b0-b4cf-b55dbf5fe930
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
72- Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites A Scanning Electron Microscopy Study.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format
Description: