Publication: Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study
dc.contributor.author | ÖZDUMAN, ZÜMRÜT CEREN | |
dc.contributor.author | Kazak, Magrur | |
dc.contributor.author | FİLDİŞİ, MEHMET ALİ | |
dc.contributor.author | ÖZLEN, RÜMEYSA HATİCE | |
dc.contributor.author | DALKILIÇ, Evrim | |
dc.contributor.author | DÖNMEZ, NAZMİYE | |
dc.contributor.institutionauthor | ÖZDUMAN, ZÜMRÜT CEREN | |
dc.contributor.institutionauthor | FİLDİŞİ, MEHMET ALİ | |
dc.contributor.institutionauthor | ÖZLEN, RÜMEYSA HATİCE | |
dc.contributor.institutionauthor | DALKILIÇ, EVRİM | |
dc.contributor.institutionauthor | DÖNMEZ, NAZMİYE | |
dc.date.accessioned | 2020-01-13T20:59:39Z | |
dc.date.available | 2020-01-13T20:59:39Z | |
dc.date.issued | 2019-01-01T00:00:00Z | |
dc.description.abstract | Objective: The aim of this study is to evaluate the microhardness and surface roughness of two different bulk-fill composites polymerized with light-curing unit (LCU) with different polymerization times before and after the application of a home bleaching agent. Materials-methods: For both microhardness and surface roughness tests, 6 groups were prepared with bulk-fill materials (SonicFill, Filtek Bulk Fill) according to different polymerization times (10, 20, and 30 s). 102 specimens were prepared using Teflon molds (4 mm depth and 5 mm diameter) and polymerized with LCU. 30 specimens (n = 5) were assessed for microhardness. Before home bleaching agent application, the bottom/top (B/T) microhardness ratio was evaluated. After bleaching agent application, the microhardness measurements were performed on top surfaces. Roughness measurements were performed in 72 specimens (n = 12) before and after bleaching application. Additionally, for SEM analyses, two specimens from all tested groups were prepared before and after bleaching agent application. The data B/T microhardness ratio before bleaching was analyzed by two-way ANOVA and Tukey's HSD test. The data from the top surface of specimens' microhardness before and after bleaching were analyzed using Wilcoxon signed-rank test, Kruskal-Wallis, Mann-Whitney U tests. The data from surface roughness tests were statistically analyzed by multivariate analysis of variance and Bonferroni test (p < 0.05). Results: The B/T microhardness ratio results revealed no significant differences between groups (p > 0.05). Comparing the microhardness values of the composites' top surfaces before and after bleaching, a significant decrease was observed exclusively in FB30s (p < 0.05). No significant differences in surface roughness values were observed when the groups were compared based on bulk-fill materials (p > 0.05) while the polymerization time affected the surface roughness of the SF20s and SF30s groups (p < 0.05). After bleaching, surface roughness values were significantly increased in the SF20s and SF30s groups (p < 0.05). Conclusion: The clinicians should adhere to the polymerization time recommended by the manufacturer to ensure the durability of the composite material in the oral environment. | en |
dc.identifier.citation | ÖZDUMAN Z. C. , Kazak M., FİLDİŞİ M. A. , ÖZLEN R. H. , DALKILIÇ E., DÖNMEZ N., -Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study-, Scanning, cilt.2019, 2019 | |
dc.identifier.doi | 10.1155/2019/2307305 | |
dc.identifier.pubmed | 31281561 | |
dc.identifier.scopus | 85069289556 | |
dc.identifier.uri | https://openaccess.bezmialem.edu.tr/handle/20.500.12645/12290 | |
dc.identifier.wos | WOS:000471944700001 | |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.title | Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: A scanning electron microscopy study | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | dca51a7b-6e9c-47f0-a499-1292ae854416 | |
local.indexed.at | PubMed | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 | |
relation.isAuthorOfPublication | 8973577b-f26e-47eb-bd38-0fb640108171 | |
relation.isAuthorOfPublication | 21a4fc1c-d033-41b0-b4cf-b55dbf5fe930 | |
relation.isAuthorOfPublication | 3b626b33-6c49-4040-bf87-c21dc9b8efb7 | |
relation.isAuthorOfPublication | 05592be3-8323-4273-bfff-96d4c4775aa8 | |
relation.isAuthorOfPublication | 290534fc-5729-4123-86c9-b3d70bded178 | |
relation.isAuthorOfPublication.latestForDiscovery | 21a4fc1c-d033-41b0-b4cf-b55dbf5fe930 |
Files
Original bundle
1 - 1 of 1
- Name:
- 72- Effect of Polymerization Time and Home Bleaching Agent on the Microhardness and Surface Roughness of Bulk-Fill Composites A Scanning Electron Microscopy Study.pdf
- Size:
- 4.01 MB
- Format:
- Adobe Portable Document Format
- Description: