Publication: Comparison of a Novel Trephine Drill with Conventional Rotary Instruments for Maxillary Sinus Floor Elevation
dc.contributor.author | Kazancioglu, Hakki Oguz | |
dc.contributor.author | Tek, Mustafa | |
dc.contributor.author | Ezirganli, Seref | |
dc.contributor.author | Mihmanli, Ahmet | |
dc.date.accessioned | 2020-10-22T15:56:00Z | |
dc.date.available | 2020-10-22T15:56:00Z | |
dc.date.issued | 2013-09-01T00:00:00Z | |
dc.description.abstract | Purpose: The purpose of this study was to compare a newly designed trephine drill (SLA KIT, Neobiotech) with conventional rotary instruments for maxillary sinus floor elevation based on operative time, postoperative pain, and perforation rates. Materials and Methods: Twenty-five patients were treated with a bilateral sinus floor elevation procedure with rotary trephine and conventional instruments. One side was treated with conventional rotary instruments, while the contralateral side was treated with rotary trephine instruments, with a 2-week gap between surgeries. Operative time was measured with a chronometer in seconds as the time from soft tissue incision to primary closure of the incision with the last suture. Pain was scored on a 10-point visual analog scale at 24 hours after surgery. The presence of tears and perforations was determined by direct visualization and the Valsalva maneuver. Results: Twenty-five patients were included in the study. Operative time was shorter when the trephine drill was used (11.1 +/- 2.4 minutes) than with conventional rotary instruments (15.1 +/- 2.9 minutes). Sinus membrane perforation was observed in eight patients when conventional rotary instruments were used, while the trephine drill resulted in two sinus perforations. Mean pain scores were 2.01 +/- 0.11 after using the trephine drill and 2.25 +/- 0.76 when conventional rotary instruments were used. No significant difference was found in postoperative pain scores. Conclusion: The trephine drill technique may result in decreased perforation rates and operative time. | |
dc.identifier.citation | Kazancioglu H. O. , Tek M., Ezirganli S., Mihmanli A., -Comparison of a Novel Trephine Drill with Conventional Rotary Instruments for Maxillary Sinus Floor Elevation-, INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, cilt.28, ss.1201-1206, 2013 | |
dc.identifier.doi | 10.11607/jomi.2708 | |
dc.identifier.scopus | 84899469924 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/23678 | |
dc.identifier.wos | WOS:000324733800019 | |
dc.title | Comparison of a Novel Trephine Drill with Conventional Rotary Instruments for Maxillary Sinus Floor Elevation | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | 4e8d7926-6cfd-4da3-a957-24dd7c3cbbbf | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 |