Publication: Comparison of Sealer Penetration Using the EndoVac Irrigation System and Conventional Needle Root Canal Irrigation
dc.contributor.author | Tuncen, Aysun Kara | |
dc.contributor.author | ÜNAL, Bayram | |
dc.date.accessioned | 2020-10-22T20:26:16Z | |
dc.date.available | 2020-10-22T20:26:16Z | |
dc.date.issued | 2014-05-01T00:00:00Z | |
dc.description.abstract | Introduction: The aim of this study was to compare the effect of the EndoVac irrigation system (SybronEndo, Orange, CA) and conventional endodontic needle irrigation on sealer penetration into dentinal tubules. Methods: Forty single-rooted, recently extracted human maxillary central incisors were randomly divided into 2 groups according to the irrigation technique used: conventional endodontic needle irrigation and EndoVac irrigation. All teeth were instrumented using the ProFile rotary system (Dentsply Maillefer, Ballaigues, Switzerland) and obturated with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) labeled with fluorescent dye. Transverse sections at 1, 3, and 5 mm from the root apex were examined using confocal laser scanning microscopy. The total percentage and maximum depth of sealer penetration were then measured. Results: Mann-Whitney test results showed that EndoVac irrigation resulted in a significantly higher percentage of sealer penetration than conventional irrigation at both the 1- and 3-mm levels (P < .05). However, no difference was found at the 5-mm level. The 5-mm sections in each group showed a significantly higher percentage and maximum depth of sealer penetration than did the 1- and 3-mm sections (P < .05). Conclusions: The EndoVac irrigation system significantly improved the sealer penetration at the 1- to 3-mm level over that of conventional endodontic needle irrigation. | |
dc.identifier.citation | Tuncen A. K. , ÜNAL B., -Comparison of Sealer Penetration Using the EndoVac Irrigation System and Conventional Needle Root Canal Irrigation-, JOURNAL OF ENDODONTICS, cilt.40, ss.613-617, 2014 | |
dc.identifier.doi | 10.1016/j.joen.2013.11.017 | |
dc.identifier.pubmed | 24767552 | |
dc.identifier.scopus | 84899628108 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/24780 | |
dc.identifier.wos | WOS:000335873200003 | |
dc.title | Comparison of Sealer Penetration Using the EndoVac Irrigation System and Conventional Needle Root Canal Irrigation | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | e5940701-2f9a-4f70-9f05-d069ea267cb2 | |
local.indexed.at | PubMed | |
local.indexed.at | WOS | |
local.indexed.at | Scopus | |
local.publication.isinternational | 1 |