Publication:
Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?

dc.contributor.authorGultekin, B. Alper
dc.contributor.authorSirali, Ali
dc.contributor.authorGultekin, Pinar
dc.contributor.authorYalcin, Serdar
dc.contributor.authorMijiritsky, Eitan
dc.date.accessioned2020-10-22T18:04:13Z
dc.date.available2020-10-22T18:04:13Z
dc.date.issued2016-01-01T00:00:00Z
dc.description.abstractPurpose. To compare marginal bone loss between subgingivally placed short-collar implants with machined collars and those with machined and laser-microtextured collars. Materials and Methods. The investigators used a retrospective study design and included patients who needed missing posterior teeth replaced with implants. Short-collar implants with identical geometries were divided into two groups: an M group, machined collar; and an L group, machined and laser-microtextured collar. Implants were evaluated according to marginal bone loss, implant success, and probing depth (PD) at 3 years of follow-up. Results. Sixty-two patients received 103 implants (56 in the M group and 47 in the L group). The cumulative survival rate was 100%. All implants showed clinically acceptable marginal bone loss, although bone resorption was lower in the L group (0.49 mm) than in the M group (1.38 mm) at 3 years (p < 0.01). A significantly shallower PD was found for the implants in the L group during follow-up (p < 0.01). Conclusions. Our results suggest predictable outcomes with regard to bone loss for both groups; however, bone resorption was less in the L group than in the M group before and after loading. The laser-microtextured collar implant may provide a shallower PD than the machined collar implant.
dc.identifier.citationGultekin B. A. , Sirali A., Gultekin P., Yalcin S., Mijiritsky E., -Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?-, BIOMED RESEARCH INTERNATIONAL, cilt.2016, 2016
dc.identifier.doi10.1155/2016/9695389
dc.identifier.pubmed27660765
dc.identifier.scopus84987723186
dc.identifier.urihttp://hdl.handle.net/20.500.12645/23937
dc.identifier.urihttps://www.hindawi.com/journals/bmri/2016/9695389/
dc.identifier.wosWOS:000383063200001
dc.subjectMarginal Bone Loss
dc.titleDoes the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?
dc.typeArticle
dspace.entity.typePublication
local.avesis.id6fadf350-0c26-4f4e-9230-5fa9185e9965
local.publication.isinternational1

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
9695389.pdf
Size:
5.02 MB
Format:
Adobe Portable Document Format
Description: