Publication: Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?
dc.contributor.author | Gultekin, B. Alper | |
dc.contributor.author | Sirali, Ali | |
dc.contributor.author | Gultekin, Pinar | |
dc.contributor.author | Yalcin, Serdar | |
dc.contributor.author | Mijiritsky, Eitan | |
dc.date.accessioned | 2020-10-22T18:04:13Z | |
dc.date.available | 2020-10-22T18:04:13Z | |
dc.date.issued | 2016-01-01T00:00:00Z | |
dc.description.abstract | Purpose. To compare marginal bone loss between subgingivally placed short-collar implants with machined collars and those with machined and laser-microtextured collars. Materials and Methods. The investigators used a retrospective study design and included patients who needed missing posterior teeth replaced with implants. Short-collar implants with identical geometries were divided into two groups: an M group, machined collar; and an L group, machined and laser-microtextured collar. Implants were evaluated according to marginal bone loss, implant success, and probing depth (PD) at 3 years of follow-up. Results. Sixty-two patients received 103 implants (56 in the M group and 47 in the L group). The cumulative survival rate was 100%. All implants showed clinically acceptable marginal bone loss, although bone resorption was lower in the L group (0.49 mm) than in the M group (1.38 mm) at 3 years (p < 0.01). A significantly shallower PD was found for the implants in the L group during follow-up (p < 0.01). Conclusions. Our results suggest predictable outcomes with regard to bone loss for both groups; however, bone resorption was less in the L group than in the M group before and after loading. The laser-microtextured collar implant may provide a shallower PD than the machined collar implant. | |
dc.identifier.citation | Gultekin B. A. , Sirali A., Gultekin P., Yalcin S., Mijiritsky E., -Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?-, BIOMED RESEARCH INTERNATIONAL, cilt.2016, 2016 | |
dc.identifier.doi | 10.1155/2016/9695389 | |
dc.identifier.pubmed | 27660765 | |
dc.identifier.scopus | 84987723186 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12645/23937 | |
dc.identifier.uri | https://www.hindawi.com/journals/bmri/2016/9695389/ | |
dc.identifier.wos | WOS:000383063200001 | |
dc.subject | Marginal Bone Loss | |
dc.title | Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar? | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.avesis.id | 6fadf350-0c26-4f4e-9230-5fa9185e9965 | |
local.indexed.at | PubMed | |