Publication:
Evaluation of various denture cleansers on color stability and surface topography of polyetherketoneketone, polyamide, and polymethylmethacrylate

dc.contributor.authorÖZYILMAZ, ÖZGÜN YUSUF
dc.contributor.authorAKIN, CEYDA
dc.contributor.authorKARA, ÖZLEM
dc.contributor.institutionauthorÖZYILMAZ, ÖZGÜN YUSUF
dc.contributor.institutionauthorKARA, ÖZLEM
dc.date.accessioned2020-09-01T20:59:47Z
dc.date.available2020-09-01T20:59:47Z
dc.date.issued2020-08-01T00:00:00Z
dc.description.abstractThe aim of this study was to evaluate the effect of sodium perborate effervescent tablets and citric acid solution on the color stability and surface topography of a new generation of high-performance polymer polyetherketoneketone (PEKK), thermoinjection-molded polyamide, and polymethylmethacrylate (PMMA). Fifty disc-shaped specimens were fabricated (10 mm x 2 mm) from PEKK (P group), polyamide (D group), and PMMA (M group). These groups were divided into five subgroups (n= 10) according to the storage media. The test groups were immersed in the following solutions: distilled water (Control), Corega, Protefix, Perlodent, and Curaprox. The color stability values (Delta E) were measured using a spectrophotometer before and after immersion in distilled water and four different denture cleansers for 8 hr/day for 140 days. Topography alterations after treatments were assessed with scanning electron microscopy (SEM). Data were analyzed by one-way analysis of variance (ANOVA) followed by Tukey-s Honest Significant Difference test. Thep < .05 was considered significant. All denture cleansers increased the Delta Evalues relative to the baseline values in the M, D, and P groups (p < .05). The Perlodent denture cleanser demonstrated the highest Delta Evalue in all groups, which was unacceptable. Curaprox denture cleanser showed the lowest Delta Evalue in the M and D groups (p < .05). Curaprox in all groups showed a increment Evalue less than 3.7. For patients who have PEKK- and polyamide-based prosthesis, the use of citric acid-based cleansers may be more recommended than sodium perborate-containing cleansers because of its clinically acceptable color changes on polymers in terms of color stability.
dc.identifier.citationÖZYILMAZ Ö. Y. , KARA Ö., AKIN C., -Evaluation of various denture cleansers on color stability and surface topography of polyetherketoneketone, polyamide, and polymethylmethacrylate-, MICROSCOPY RESEARCH AND TECHNIQUE, 2020
dc.identifier.doi10.1002/jemt.23558
dc.identifier.pubmed32757255
dc.identifier.scopus85088927963
dc.identifier.urihttp://hdl.handle.net/20.500.12645/18515
dc.identifier.wosWOS:000555494900001
dc.language.isoen
dc.titleEvaluation of various denture cleansers on color stability and surface topography of polyetherketoneketone, polyamide, and polymethylmethacrylate
dc.typeArticle
dspace.entity.typePublication
local.avesis.id40a7104b-e4bc-4073-abaa-4ed54e7d25e4
local.publication.isinternational1
relation.isAuthorOfPublication93fb2c3e-3713-4ef4-ac48-cc42ffaf2a31
relation.isAuthorOfPublication252d2fa3-986f-4bd5-83da-07e178896107
relation.isAuthorOfPublication.latestForDiscovery93fb2c3e-3713-4ef4-ac48-cc42ffaf2a31
Files