Publication:
Farklı Pürüzlendirme Tekniklerinin Braket Çevresinde Mine Demineralizasyonu Oluşturma Etkilerinin Karşılaştırılması / Comparison of Enamel Demineralization Around Orthodontic Brackets With Different Etching Techniques

dc.contributor.advisorProf. Dr. Serdar ÜŞÜMEZ
dc.contributor.authorAYDIN ÖZÇOBAN, Yasemin
dc.date.accessioned2020-10-19T08:31:19Z
dc.date.available2020-10-19T08:31:19Z
dc.date.issued2016-03
dc.descriptionThesis (dentistry)--Bezmialem Vakıf University, Faculty of Dentistry, Department of Orthodontics, Istanbul, 2016
dc.description.abstractDemineralization areas around the brackets observed during orthodontic treatment are of great interest for the orthodontist as demineralization of enamel adjacent to fixed orthodontic appliances can be an esthetic problem for the patient, as well as a problem for the doctor that overshadows the success of the treatment. A new Er:YAG laser handpiece (X-runner) is unique in its ability to digitally control size, shape and depth of irradiated enamel area. This study evaluated the enamel demineralization around brackets bonded following different etching techniques. In this study, total of 100 premolars were divided into four equal groups and received the following treatments: Group 1 Total Etch, acid etching; Group 2 Self Etch, self-etching; Group 3 Lazer M, manual Er:YAG laser etching; Group 4 Lazer X, Er:YAG laser etching with X-Runner handpiece. After placing the brackets, the teeth were cycled through a demineralization-remineralization procedure for 14 days. The solutions were changed daily in order to simulate the saliva flow in the mouth. The teeth were brushed manually with a soft-bristled toothbrush for 30 seconds between each cycle to simulate mechanical wear. The mineral loss on the enamel surface was assessed using Quantitative Light-Induced Fluorescence (QLF). As a result of analysis of QLF four different parameters including ∆F, ∆F max, ∆Q and Area were obtained. Kruskal Wallis test was used for comparisons of parameters between groups. Mann Whitney U test was used in the determination of the group that caused the differences. According to statistical evaluation of the results of QLF analysis there were significant differences among groups for four different parameters (p<0.01). In acid-etch group enamel demineralization around the brackets was significantly higher compared to other experimental groups (p<0.01). Furthermore, demineralization observed in X-runner group was significantly lower compared to manual Er:YAG laser group (p<0.05). There were no significant differences between other groups (p>0.05). Within the limitations of this study, Er:YAG laser etching with X-runner handpiece was considered to be favorable for prevention of enamel demineralization in vitro.en
dc.description.abstract{{abstract}}
dc.identifier.urihttp://hdl.handle.net/20.500.12645/23088
dc.language.isotrtr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectDental mine : Dental enametr_TR
dc.subjectDiş demineralizasyonu : Tooth demineralizationtr_TR
dc.subjectLazerler : Laserstr_TR
dc.subjectMine : Enameltr_TR
dc.subjectOrtodonti : Orthodonticstr_TR
dc.subjectOrtodontik aygıtlar : Orthodontic appliancestr_TR
dc.subjectOrtodontik braketler : Orthodontic bracketstr_TR
dc.subjectYüzey pürüzlülüğü : Surface roughnesstr_TR
dc.subjectDiş Hekimliği = Dentistry
dc.titleFarklı Pürüzlendirme Tekniklerinin Braket Çevresinde Mine Demineralizasyonu Oluşturma Etkilerinin Karşılaştırılması / Comparison of Enamel Demineralization Around Orthodontic Brackets With Different Etching Techniquestr_TR
dc.title.alternative
dc.typeThesistr_TR
dspace.entity.typePublication
local.thesis.programnameOrtodonti Anabilim Dalıtr
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
460383.pdf
Size:
12.14 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.14 KB
Format:
Item-specific license agreed upon to submission
Description: