Person:
KARA, ÖZLEM

Loading...
Profile Picture
Status
Organizational Units
Job Title
First Name
ÖZLEM
Last Name
KARA
Name
Email Address
Birth Date

Search Results

Now showing 1 - 3 of 3
  • PublicationMetadata only
    Custom Cast Post Treatment on an Implant Platform in 2 Patients
    (2015-08-01) DİLBER, Erhan; BAYTAROĞLU, Ebru Nur; Kara, Haluk Baris; Kara, Ozlem; KARA, ÖZLEM
  • PublicationMetadata only
    Effect of Various Lasers on the Bond Strength of Two Zirconia Ceramics
    (2015-02-01) Kara, Ozlem; Kara, Haluk Baris; Tobi, Elif Sumeyye; Ozturk, Atiye Nilgun; Kilic, Hamdi Sukur; KARA, ÖZLEM
    Objective: The purpose of this study was to compare and evaluate the effects of various laser systems on surface roughness and shear bond strengths of zirconia ceramics. Material and methods: Seventy-two ceramic discs (10 mmx2 mm) obtained from two sintered zirconia ceramics (Zirkonzahn, Zirkonzahn Prettau((R))) were divided into two groups (n=36) according to the computer-aided design (CAD)-computer-aided manufacturing (CAM) technique and then further divided into three groups (n=12). Each group was treated with one of the following: (1) femtosecond (FS), (2) Nd:YAG (NY), and (3) Er:YAG (EY) lasers. After laser irradiation, a scanning electron micrograph (SEM) was taken at 500x magnification for qualitative examination. Following surface roughness measurement by profilometry, resin cement (Rely X U200) was bonded to the ceramic specimens using Teflon tubes (3 mm height, 4 mm diameter). Specimens were stored in distilled water at 37 degrees C for 24 h and then thermal cycled for 5000 cycles. A shear bond strength (MPa) test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed by two way analysis of variance (ANOVA) and Tukey honest significant difference (HSD) tests for pairwise comparisons among groups (p=0.05). Results: MPa and roughness were significantly affected by laser type (p0.05). In the SEM, the surfaces of the FS group were rougher than those of the NY and EY groups. NY and EY surfaces were nearly smooth. Conclusions: FS laser is an effective surface treatment for roughening surfaces of zirconia ceramics. Furthermore, it reveals the highest MPa.
  • PublicationOpen Access
    Effects of various denture cleansers on surface roughness of hard permanent reline resins
    (2015-04-01) Cakan, Umut; Kara, Ozlem; Kara, Haluk Baris; KARA, ÖZLEM
    The aim of this study was to investigate the influence of denture cleansers on surface roughness (Ha, mu m) of two hard permanent reline resins and a conventional acrylic denture base resin. Fifty specimens of each material, measuring 10 mmx2 mm were randomly divided into 1 control and 4 experimental subgroups (n=10). Surface roughness values were measured using profilometer before and after immersion in distilled water and in 4 different denture cleansers for 8 h for 140 days. The Kruskal Wallis and Wilcoxon Signed Ranks tests were used for comparison among groups with a significance level of alpha=0.05. Immersion in denture cleansers significantly increased the surface roughness of reline resins and the difference among the cleansers was statistically significant (p=0.059). Denture cleansers can cause significant surface roughness alterations on hard permanent reline resins and denture base resin where their effect may differ according to the selected resin material.