Person:
TIRIS, GİZEM

Loading...
Profile Picture
Status
Organizational Units
Job Title
First Name
GİZEM
Last Name
TIRIS
Name
Email Address
Birth Date

Search Results

Now showing 1 - 2 of 2
  • PublicationMetadata only
    High performance liquid chromatographic analysis of lercanidipine in human breast milk
    (2019-01-01) Tekkeli, Evrim Kepekci; GAZİOĞLU, IŞIL; TIRIS, GİZEM; Onal, Cem; TEKKELİ, ŞERİFE EVRİM; GAZİOĞLU, IŞIL; TIRIS, GİZEM
    A simple, rapid, precise and accurate isocratic reversed phase HPLC method was developed and validated for the determination of lercanidipine hydrochloride in pharmaceutical tablets and spiked human breast milk. The chromatographic separation was achieved on C18 (250x4.6 mmx5 mu m) column using a mobile phase consisting of acetonitrile and phospate buffer (pH=4) (55:45, v/v) at a flow rate of 1.1 mL/min and UV detection at 237 nm. The linearity of the proposed method was investigated in the range of 1.0-40 mu g/mL (r(2)=0.9990). The method was validated in terms of accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. The proposed method is found as suitable for routine quantification of lercanidipine in human breast milk.
  • PublicationMetadata only
    Ultra fast liquid chromatographic analysis of nonsteroidal anti-inflammatory drugs with fluorimetric detection in tap water, urine, and pharmaceutical samples
    (2022-06-01T00:00:00Z) Onal, Cem; TIRIS, GİZEM; Tekkeli, Evrim Kepekci; Onal, Armagan; TIRIS, GİZEM; TEKKELİ, ŞERİFE EVRİM
    A novel analytical method based on ultra-fast liquid chromatography using fluorimetric detector was developed and validated for determination of non-steroidal anti-inflammatory drugs (NSAIDs) (ibuprofen (IBP), etodolac (ETD), dexketoprofen (DKP), sodium diclofenac (SDCF), and naproxen (NPX) in tap water, urine and pharmaceutical samples. Precolumn derivatisation of targeted NSAIDs was carried out with 4-bromomethyl-7-methoxy coumarin (BrMmC) using dibenzo-18-crown-6-ether as reaction catalyst leading to the formation of a fluorescent compound. The obtained fluorescent compound of NSAIDs were measured at excitation wavelength as 325 nm, and emission wavelength of 395 nm. Optimum analytical conditions were carefully studied and improved. C18 column, with the dimensions of 4.0 x 100 mm and 3 mu m particle size, was used. Gradient elution with methanol: water 40:60; v/v (eluent A) and acetonitrile 100% (eluent B) were used as mobile phase and flow rate of 0.4 mL/min. The linearity range of the analytes were between 0.01-10.0 mu g mL(-1). Recovery values obtained from pharmaceutical preparations were found as 100.04%, 99.99%, 100.09%, 99.98% and 100.47% for IBP, ETO, DKP, SDCF, NPX, respectively. LOD values were found to vary between 0.00009 mu g mL(-1) and 0.00048 mu g mL(-1) in tap water, urine and pharmaceutical samples. The optimised technique was successfully applied for the determination of NSAIDs in tap water, urine, and pharmaceutical specimen. The specified NSAIDs were not found in real tap water samples.