Publication:
A Multicenter Experience of Thrombotic Microangiopathies in Turkey: The Turkish Hematology Research and Education Group (ThREG)-TMA01 Study

dc.contributor.authorTekgunduz, Emre; Yilmaz, Mehmet; Erkurt, Mehmet Ali; Kiki, Ilhami; Kaya, Ali Hakan; Kaynar, Leylagul; Alacacioglu, Inci; Cetin, Guven; Ozarslan, Ibrahim; Kuku, Irfan; Sincan, Gulden; Salim, Ozan; Namdaroglu, Sinem; Karakus, Abdullah; Karakus, Volkan; Pamuk, Gulsum Emel; Altuntas, Fevzi; Sari, Hakan Ismail; Ozet, Gulsum; Aydogdu, Ismet; Okan, Vahap; Kaya, Emin; Yildirim, Rahsan; Yildizhan, Esra; Ozgur, Gokhan; Ozcebe, Osman Ilhami; Payzin, Bahriye; Akpinar, Seval; Demirkan, Fatih
dc.date.accessioned2021-03-14T19:17:52Z
dc.date.available2021-03-14T19:17:52Z
dc.date.issued1.12.2016
dc.description.abstractIn this study, we propose a novel cooling dehumidifying strategy, in which a condensing panel can be hydronically connected in series with the radiant cooling system to overcome condensation risk and improve indoor thermal comfort level. Based on the concept, the sensible heat-load is primarily covered by radiant cooling panels and some amount of latent heat and sensible heat can be treated by the condensing panel, while improving indoor thermal comfort level. Since, the surface temperature of the condensing panel is lower than the dew point temperature, while the radiant surface is higher for same supply water temperatures - condensation occurs only over the condensing plate. This paper evaluates the thermal comfort performance of the proposed novel condensing panel. For these aim, a new experimental chamber was developed. General thermal comfort level and the temperature, relative humidity ratio distribution in the tested room were evaluated for 10 different experimental cases. Multiple tests were conducted by varying surface temperature of the condensing panel and initial relative humidity ratios of air in the room. The results show that proposed simple solution can improve thermal comfort level, for the places where the latent heat loads are not considerable high, and reduce the condensation risk over the radiant cooling panels.
dc.identifier.doi10.1182/blood.V128.22.4933.4933
dc.identifier.eissn1528-0020
dc.identifier.issn0006-4971
dc.identifier.urihttp://hdl.handle.net/20.500.12645/28542
dc.identifier.urihttps://doi.org/10.1182/blood.V128.22.4933.4933
dc.identifier.wosWOS:000394452701139
dc.language.isoen
dc.subjectRadiant cooling; condensing panel; thermal comfort
dc.titleA Multicenter Experience of Thrombotic Microangiopathies in Turkey: The Turkish Hematology Research and Education Group (ThREG)-TMA01 Study
dc.typeMeeting Abstract
dspace.entity.typePublication
Files