Person:
KARA, ÖZLEM

Loading...
Profile Picture
Status
Organizational Units
Job Title
First Name
ÖZLEM
Last Name
KARA
Name
Email Address
Birth Date

Search Results

Now showing 1 - 4 of 4
  • PublicationOpen Access
    In vitro study of fracture strength of provisional crown materials
    (2015-02-01) Karaokutan, Isil; Sayin, Gulsum; Kara, Ozlem; KARA, ÖZLEM
    PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at 37°C for 24 hours, and then they were thermocycled (TC, 5000×, 5-55°C) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (α=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique. [J Adv Prosthodont 2015;7:27-31]
  • PublicationOpen Access
    Mechanical properties of zirconia after different surface treatments and repeated firings
    (2014-12-01) Subasi, Meryem Gulce; Demir, Necla; Kara, Ozlem; Ozturk, A. Nilgun; Ozel, Faruk; KARA, ÖZLEM
    This study investigated the influence of surface conditioning procedures and repeated firings on monoclinic content and strength of zirconia before cementation. MATERIALS AND METHODS. Sintered barshaped zirconia specimens were subjected to no surface treatment (control), air abrasion, or grinding (n=21). Their roughness was evaluated using a profilometer, and microscope analysis was performed on one specimen of each group. Then, 2 or 10 repeated firings (n=10) were executed, the monoclinic content of specimens was analyzed by X-ray diffraction, and a three-point flexural strength test was performed. Surface roughness values were compared using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests, the monoclinic content values were tested using Kruskal-Wallis and Mann-Whitney U tests, and the flexural strength values were tested using two-way ANOVA and Tukey HSD tests (P=.05). Spearman’s correlation test was performed to define relationships among measured parameters. RESULTS. Surface-treated specimens were rougher than untreated specimens and had a higher monoclinic content (P<.005), and the relationship between roughness and monoclinic content was significant (P<.000). Neither surface treatment nor firing significantly affected the flexural strength, but Weibull analysis showed that for the air-abraded samples the characteristic strength was significantly lower after the 10th firing than after the 2nd firing. CONCLUSION. After firing, a negligible amount of monoclinic content remained on the zirconia surfaces, and rougher surfaces had higher monoclinic contents than untreated surfaces. Multiple firings could be performed if necessary, but the fracture probability could increase after multiple firings for rougher surfaces
  • PublicationOpen Access
    Effects of various denture cleansers on surface roughness of hard permanent reline resins
    (2015-04-01) Cakan, Umut; Kara, Ozlem; Kara, Haluk Baris; KARA, ÖZLEM
    The aim of this study was to investigate the influence of denture cleansers on surface roughness (Ha, mu m) of two hard permanent reline resins and a conventional acrylic denture base resin. Fifty specimens of each material, measuring 10 mmx2 mm were randomly divided into 1 control and 4 experimental subgroups (n=10). Surface roughness values were measured using profilometer before and after immersion in distilled water and in 4 different denture cleansers for 8 h for 140 days. The Kruskal Wallis and Wilcoxon Signed Ranks tests were used for comparison among groups with a significance level of alpha=0.05. Immersion in denture cleansers significantly increased the surface roughness of reline resins and the difference among the cleansers was statistically significant (p=0.059). Denture cleansers can cause significant surface roughness alterations on hard permanent reline resins and denture base resin where their effect may differ according to the selected resin material.
  • PublicationMetadata only
    The metameric effect of monolithic zirconias with varying yttrium ratios
    (2024-01-01) Güven M. E.; KARA Ö.; GÜVEN, MEHMET EJDER; KARA, ÖZLEM
    PURPOSE. To evaluate the metameric disparities among monolithic zirconia materials with differing yttrium compositions across various lighting conditions. MATERIALS AND METHODS. Thirty-six square-shaped zirconia samples measuring 10 X 10 X 0.5 mm were prepared from monolithic zirconia materials with three different yttrium contents. A 0.2 mm thick layer of polymerized dual-polymerizable self-adhesive resin cement was created using a silicone mold with the same dimensions as the prepared zirconia specimens. To evaluate metamerism, color measurements were conducted using a spectrophotometer device on a neutral gray background in a color measurement cabinet that offers four different illumination environments. All samples underwent aging by subjecting them to 10000 thermal cycles using a thermal cycle tester. Following thermal aging, color measurements were taken once more, and the data were recorded using the CIE L*, a*, b* color system. Two-way ANOVA and Post-hoc Bonferroni tests were employed to analyze the data. RESULTS. It was observed that there was no statistical difference among the color measurements made in different illumination environments of the monolithic zirconia ceramics used to evaluate metamerism P(>. 05). This observation remained consistent both before and after thermal aging. After thermal aging, the color of monolithic zirconia materials exhibited a tendency towards red and yellow hues, accompanied by a decrease in brightness levels. CONCLUSION. It can be stated that different illumination conditions did not affect the metamerism of monolithic zirconia materials, but there was a color change in monolithic zirconia materials after a thermal aging period equivalent to one year. [J Adv Prosthodont 2024;16:48-56]