Publication:
A New Anchor Augmentation Technique With a Cancellous Screw in Osteoporotic Rotator Cuff Repair: An In Vitro Biomechanical Study on Sheep Humerus Specimens

No Thumbnail Available
Date
2014-01-01T00:00:00Z
Authors
URUÇ, VEDAT
Ozden, Raif
DOĞRAMACI, YUNUS
KALACI, AYDINER
Hallaceli, Hasan
KÜÇÜKDURMAZ, FATİH
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue

Metrics

Search on Google Scholar

Abstract
Purpose: The aim of this study was to test a simple technique to augment the pullout resistance of an anchor in an over-drilled sheep humerus model. Methods: Sixty-four paired sheep humeri were harvested from 32 male sheep aged 18 months. Specimens were divided into an augmented group and non-augmented group. FASTIN RC 5-mm titanium screw anchors (DePuy Mitek, Raynham, MA) double loaded with suture material (braided polyester, nonabsorbable USP No. 2) were used in both groups. Osteoporosis was simulated by over-drilling with a 4.5-mm drill. Augmentation was performed by fixing 1 of the sutures 1.5 cm inferior to the anchor insertion site with a washer screw. This was followed by a pull-to-failure test at 50 mm/min. The ultimate load (the highest value of strength before anchor pullout) was recorded. A paired t test was used to compare the biomechanical properties of the augmented and non-augmented groups. Results: In all specimens the failure mode was pullout of the anchor. The ultimate failure loads were statistically significantly higher in the augmented group (P < .0001). The mean pullout strength was 121.1 +/- 10.17 N in the non-augmented group and 176.1 +/- 10.34 N in the augmented group. Conclusions: The described augmentation technique, which is achieved by inferior-lateral fixation of 1 of the sutures of the double-loaded anchor to a fully threaded 6.5-mm cancellous screw with a washer, significantly increases the ultimate failure loads in the over-drilled sheep humerus model. Clinical Relevance: Our technique is simple, safe, and inexpensive. It can be easily used in all osteoporotic patients and will contribute to the reduction of anchor failure. This technique might be difficult to apply arthroscopically. Cannulated smaller screws would probably be more practical for arthroscopic use. Further clinical studies are needed.
Description
Keywords
Citation
URUÇ V., Ozden R., DOĞRAMACI Y., KALACI A., Hallaceli H., KÜÇÜKDURMAZ F., -A New Anchor Augmentation Technique With a Cancellous Screw in Osteoporotic Rotator Cuff Repair: An In Vitro Biomechanical Study on Sheep Humerus Specimens-, ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, cilt.30, ss.16-21, 2014
Page Views

0

File Downloads

0

Sustainable Development Goals