Person:
ERSOY, YELIZ EMINE

Loading...
Profile Picture
Status
Organizational Units
Organizational Unit
Job Title
First Name
YELIZ EMINE
Last Name
ERSOY
Name
Email Address
Birth Date

Search Results

Now showing 1 - 7 of 7
  • PublicationMetadata only
    Evaluation of Parathyroid allo-transplantation with the Presence of Auto-CASR Antibody
    (2022-05-01) Selepcioğlu Kaya H.; Göncü B. S.; Ersoy Y. E.; Akçakaya A.; SELEPCİOĞLU KAYA, HARİKA; GÖNCÜ, BEYZA SERVET; ERSOY, YELIZ EMINE; AKÇAKAYA, ADEM
  • PublicationMetadata only
    Hücre Mikroenkapsülasyonunda Manuel ve Kapsülasyon Sisteminin Hücre İzolasyon Tipi ve Aljinat Yüzdesine Bağlı Verimliliğinin Karşılaştırılması
    (2021-08-01T00:00:00Z) Düzenli, Ömer Faruk; Göncü, Beyza Servet; Selepcioğlu, Harika; Yücesan, Emrah; Ersoy, Yeliz Emine; Akçakaya, Adem; GÖNCÜ, BEYZA SERVET; YÜCESAN, EMRAH; ERSOY, YELIZ EMINE; AKÇAKAYA, ADEM
    Amaç: Birçok endüstriyel sektörde kullanılan polimer malzemeler sağlık bilimlerinde de farklı işlemlerde kullanılmaktadır. Bu işlemlerden biri olan enkapsülasyon sistemi hücre nakli gibi terapötik uygulamalarda tercih edilmektedir. Enkapsülasyon çalışmalarında uygulanacak yaklaşıma göre kapsül yapısında kullanılacak polimer malzeme ve oluşan kapsül boyutu değişmektedir. Aljinat, kahverengi alglerden elde edilen, içeriğindeki farklı polimerik blok oranlarına bağlı olarak değişiklik gösteren doğal polimerlerden biridir. Bu çalışmada, kapsülasyon aşaması için kullanılacak olan değişik aljinat yüzdeleri uygulanarak paratiroid hücrelerinde ideal mikroenkapsülasyon prosedürlerinin belirlenmesi amaçlanmaktadır.Gereç ve Yöntem: Çalışmada sekonder hiperparatiroidi hastasından alınan bir adet paratiroid hiperplazi dokusundan mekanik ve enzimatik izolasyon yöntemleriyle hücre eldesi gerçekleştirilmiştir. İki farklı aljinat yüzdesi kullanarak hem manuel olarak hem de kapsülasyon cihazında otomatize olarak iki farklı akış hızı değerlendirilmiştir. Mikroenkapsüle edilen hücreler 64-79 gün boyunca in vitro olarak parathormon miktarları ölçülerek takip edilmiştir.Bulgular: Değerlendirilen aljinat yüzdelerinden %2’lik konsantrasyona sahip mikroenkapsüllerin oluşturulmasında kapsülasyon cihazında kullanılan 2 mL/dk akış hızıyla morfolojik stabilite gözlenmiştir. Ayrıca parathormon salınımı açısından hücre izolasyon tipi ve aljinat yüzdeleri arasında benzer sonuçlar elde edilmiştir.Sonuç: Uzun süreli mikroenkapsülasyon verimliliğinin arttırılması için yapısal ve fonksiyonel açıdan birçok parametrenin belirlenmesi gerekmektedir. Bu çalışma ile enzimatik izolasyon metoduyla elde edilen paratiroid hücrelerinin kapsülasyon sistemi kullanılarak artan akış hızında daha stabil bir yapı oluşturdukları belirlenmiştir.
  • PublicationMetadata only
    Stem cell markers: A guide to neoadjuvant therapy in breast carcinomas
    (2022-06-01T00:00:00Z) Gücin, Zühal; Büyükpınarbaşılı, Nur; Geçer, Melin; Ersoy, Yeliz Emine; Türk, Hacı Mehmet; Yıldız, Şeyma; Aksoy, Direnç Özlem; GÜCİN, ZÜHAL; GEÇER, MELİN; ERSOY, YELIZ EMINE; TÜRK, HACI MEHMET; YILDIZ, ŞEYMA
    BACKGROUND: In recent years, stem cells have been defined as the main cell population responsible for resistance to anticancer therapies. AIM: This study aims to investigate potential associations between the stem cell population and the degree of tumor regression in breast carcinomas treated with neoadjuvant therapy. SETTINGS AND DESIGN: The study included 92 patients with breast carcinoma who received neoadjuvant therapy. Tumor regression was defined based on Miller and Payne grading system. Patients with grade 1 or 2 regression on a 5‑point scale were included in group 1 (n = 37), grade 3 regression in group 2 (n = 32), and grade 4 or 5 regression in group 3 (n = 23). MATERIALS AND METHODS: Immunohistochemical staining was performed on paraffin block sections of every case using CD44, CD24, CD29, CD133, ID4, and ALDH1 antibodies to detect stem cells. STATISTICAL ANALYSIS USED: IBM Statistical Package for the Social Sciences (SPSS), version 23.0 (IBM Corp., Armonk, NY, USA) software was used for statistical analyses, and a P value less than 0.05 was considered statistically significant. RESULTS: Histologically high‑grade tumors are more common in the near‑complete/complete response group (P = 0.004). HER2‑positive tumors were more common in the complete/ near‑complete response group (P = 0.054). Tumor cells positive for stem cell markers CD44 and CD24 were more common in the poor response group (P = 0.027 and P = 0.001, respectively). CD29 expression was reduced in the posttreatment residual tumor tissue in the near‑complete/complete response group. CONCLUSION: High CD44 and CD24 expression may be a predictor of poor response/nonresponse to neoadjuvant therapy in breast carcinomas. KEY WORDS: Breast Cancers, neoadjuvant treatment, stem cell markers, stem cells, tumor regression grade
  • PublicationMetadata only
    The Effect of Intravenously Paratyroid Cell Xenotransplantation in Sheep: As an Animal Model
    (2020-08-01T00:00:00Z) İdiz, Oğuz; Yücesan, Emrah; Ayşan, Erhan; Özdemir, Burcu; Uçak, Ramazan; Göncü, Beyza; Kanımdan, Ebru; Ersoy, Yeliz Emine; YÜCESAN, EMRAH; GÖNCÜ, BEYZA SERVET; KANIMDAN, EBRU; ERSOY, YELIZ EMINE
  • PublicationMetadata only
    EVALUATION OF EPIDEMIOLOGICAL FEATURES OF PERMANENT HYPOPARATHYROIDISM PATIENTS WHILE AS A CANDIDATE OF PARATHYROID TRANSPLANTATION
    (2021-08-01T00:00:00Z) Kaya, Harika Salepcioglu; GÖNCÜ, BEYZA SERVET; Karatoprak, Utku; Duzenli, Omer Faruk; YÜCESAN, Emrah; ERSOY, Yeliz Emine; KAZANCIOĞLU, Rümeyza; AKÇAKAYA, Adem; GÖNCÜ, BEYZA SERVET; YÜCESAN, EMRAH; ERSOY, YELIZ EMINE; KAZANCIOĞLU, RÜMEYZA; AKÇAKAYA, ADEM
  • PublicationMetadata only
    Analysis of the DOK1 gene in breast cancer
    (2020-01-01T00:00:00Z) Tuna, Esin; ERSOY, YELİZ EMİNE; Bulut, Pelin; Ozdemir, Filiz; Buyru, Nur; ERSOY, YELIZ EMINE
  • PublicationMetadata only
    Mikroenkapsülasyon Sisteminin Aljinat-Hücre Süspansiyon Yoğunluğuna Bağlı Hızlarının Değerlendirilmesi
    (2021-09-01T00:00:00Z) Göncü, Beyza Servet; Akçakaya, Adem; Ersoy, Yeliz Emine; Selepcioğlu, Harika; Yücesan, Emrah; GÖNCÜ, BEYZA SERVET; YÜCESAN, EMRAH; ERSOY, YELIZ EMINE; AKÇAKAYA, ADEM
    Amaç: Mikroenkapsülasyon tekniği sağlık bilimlerinde ilaç veya hücre gibi terapötik araçların bir kaplayıcı malzeme ile kaplanarak hem taşınımı hem de muhafazasını sağlamak amacıyla kullanılmaktadır. Kaplayıcı materyal olarak doğal olan ve olmayan birçok polimerik malzeme kullanılmaktadır. Bunlar arasında biyouyumluluğu ve yapısal stabilitesinden dolayı ultra saf aljinat avantajlı konumdadır. Bu çalışmada ultra saf aljinat ile paratiroit hücreleri kullanılarak mikroenkapsülasyon için ideal aljinat-hücre süspansiyon oranını, uygun hücre izolasyon metodunu ve mikroenkapsülasyon oluşturmak için kullanılan sistemin en uygun akış hızını belirlemek amaçlanmıştır.Gereç ve Yöntem: Çalışmada dört ayrı paratiroit dokusundan, iki farklı izolasyonla (enzimatik/mekanik) elde edilen paratiroit hücreleri kullanılmıştır. Hücreler serum fizyolojik ile süspanse hale getirilerek farklı miktarlarda aljinat ile enkapsüle edilmiştir. Sonrasında belirlenen aljinat-hücre süspansiyon oranları, iki farklı izolasyonla elde edilen paratiroit hücreleri ile farklı akış hızlarında enkapsüle edilerek in vitro olarak morfolojileri ve hücrelerin salgıladığı parathormon miktarı takip edilmiştir.Bulgular: Morfolojik olarak 500μL:200μL (aljinat:hücre süspansiyon hacmi) oranında hazırlanan enkapsüllerin in vitro olarak verimli olduğu belirlenmiştir. Böylelikle %28 oranında aljinat-hücre süspansiyon oranı sabit tutularak; mekanik izolasyonlu hücrelerin kullanıldığı mikroenkapsüllerin morfoloji ve cihazın akış hızına negatif etki oluşturduğu belirlenmiştir. Yalnızca enzimatik hücre izolasyonu yapılan paratiroit hücreleri farklı akış hızlarında morfolojik farklılıklar oluşturmuş ve 2,5mL/dakika hızın yapı, salgıladıkları parathormon ve stabilite açısından verimli oldukları belirlenmiştir.Sonuç: Hücrelerin salgıladığı ürünlerin kapsül alanı dışına ulaşması hücre mikroenkapsülasyonunun temel işleyişini oluşturmaktadır. Yapısal stabilitenin korunması, mikroenkapsüle edilen hücrelerin etkin şekilde beslenmesine olanak sağlamalıdır. Ayrıca bu çalışma ile aljinat-hücre süspansiyon oranı, uygun hücre izolasyon metodu ve akış hızı sınırları netleştirilmiştir. Gelecek çalışmalarla belirlenen değerlerin uzun in vitro takiplerinin yapılması gerekmektedir.