Person:
KÜTÜK, MEHMET SERDAR

Loading...
Profile Picture
Status
Kurumdan Ayrılmıştır.
Organizational Units
Organizational Unit
Job Title
First Name
MEHMET SERDAR
Last Name
KÜTÜK
Name
Email Address
Birth Date

Search Results

Now showing 1 - 4 of 4
  • PublicationMetadata only
    The Role of the Urine Dipstick Test in the Detection of Abnormal Proteinuria Using Different Cut-off Levels in Hypertensive Pregnancies Hipertansif Gebeliklerde Farklı Kesim Değerleri Kullanılarak Anormal Proteinüri Saptanmasında Spot İdrar Protein Ölçümünün Rolü
    (2022-01-01) Takmaz T.; Gorchiyeva I.; Arici Halici B. N.; TOPRAK A.; ÇETİN Ç.; KÜTÜK M. S.; TAKMAZ, TAHA; ARICI HALICI, BELFİN NUR; TOPRAK, ALİ; ÇETİN, ÇAĞLAR; KÜTÜK, MEHMET SERDAR
    © 2022, Duzce University Medical School. All rights reserved.Aim: The aim of this study was to determine the diagnostic accuracy of different urine dipstick protein threshold levels in predicting the presence of abnormal proteinuria in pregnant women with hypertension. Material and Methods: A total of 326 singleton pregnant women who underwent 501 urine protein tests and who had suspected preeclampsia were included in this retrospective study. Patient data was taken including medical and obstetric history. The results of dipstick urinalysis and concurrent 24-hour urine protein excretion measurements were compared to determine the accuracy of urinalysis. Results: A dipstick result of 1+ was found to be the best cut-off to predict 500 mg of protein excretion per day, with sensitivity and specificity of 62.09% and 88.97%, respectively. A 2+ proteinuria dipstick cut-off had high specificity and positive predictive value (PPV) (99.05% and 98.84%, respectively) for the prediction of 300 mg of protein excretion per day; this cut-off had low sensitivity (21.46%). A cut-off of 1+ also provided satisfactory specificity and PPV (91.43% and 94.48%, respectively) for the detection of 300 mg of protein excretion per day, but sensitivity was compromised (38.89%). Among 301 patients with negative dipstick results, 212 had a 24-hour urine protein extraction greater than 300 mg, with a false negative rate of 70.43%. Conclusion: The results suggest that the urine protein dipstick measurement has limited quantitative ability for the prediction of abnormal proteinuria. Additionally, the use of 500 mg 24-hours protein excretion as a cut-off value for abnormal proteinuria may provide useful data.
  • PublicationMetadata only
    Prenatal Sonographic Detection of Monochorionic Twins with Bipartite Placenta
    (2020-02-10T04:00:00Z) KÜTÜK, MEHMET SERDAR; TAKMAZ, TAHA; Bayram, Arslan; Ozturk, Sule; KÜTÜK, MEHMET SERDAR; TAKMAZ, TAHA
    Background: Determination of placentation and amnionicity is important for antenatal and intrapartum management in twin gestations. We present an typical monozygotic twin placenta and underscore the sonographic features and diagnostic pitfalls that may interfere with antenatal diagnosis. Case report: A 35-year-old G4P2 with a spontaneous pregnancy applied for routine second trimester anomaly screening. Upon prenatal ultrasonography at 20 weeks, an anatomically normal, same sex twin pregnancy was detected. A thin dividing membrane and a T-sign suggestive of a monochorionic diamniotic pregnancy were visualized. Antenatal follow-up was uneventful. Cesarean delivery was performed at 37 week. Postpartum examination revealed two distinct placental discs connected with each other through membranes. Microscopic examination of the membranes supported monochorionicity. Short Tandem Repeat Profile Analysis revealed identical pattern and confirmed monozygosity. Conclusion: Two separate placentas with a T-sign in same-sex twins should raise the suspicion of monozygosity, and should be followed accordingly.
  • PublicationMetadata only
    Prenatal Ultrasound Detection of Mirror Twins With a Fused Proximal Umbilical Cord
    (2019-10-30T00:00:00Z) KÜTÜK, MEHMET SERDAR; Sahin, NURHAN; TAKMAZ, TAHA; KÜTÜK, MEHMET SERDAR; ŞAHİN, NURHAN; TAKMAZ, TAHA
  • PublicationMetadata only
    Incidence and outcomes of eclampsia: a single-center 30-year study
    (2019-04-01T00:00:00Z) Uludag, Semih Zeki; Karasu, AYŞE FİLİZ; KÜTÜK, MEHMET SERDAR; TAKMAZ, TAHA; GÖKMEN KARASU, AYŞE FİLİZ; KÜTÜK, MEHMET SERDAR; TAKMAZ, TAHA
    Objective: We aimed to determine the incidence of eclampsia at Erciyes University Hospital which is a tertiary referral center situated at central Anatolia. Additionally, we investigated eclampsia-associated maternal and perinatal outcomes for the 30-year study period. Methods: A retrospective review was performed for all women who were diagnosed with eclampsia and admitted to the Erciyes University Medical School, Department of Obstetrics and Gynecology from January 1985 to December 2015. Improvement in management gained over time was determined by comparing the results of the years 2005-2015 with data which were already published from years 1985-1999 and 2000-2004. Results: Eclampsia prevalence was 289/46,928 (% 0.61). Maternal age at the time of diagnosis did not differ statistically; however, gestational age at diagnosis and birth weight decreased significantly throughout the years (p < 0.005). The perinatal mortality rate showed a slight decrease throughout the years (p = 0.238). Maternal mortality rate also decreased throughout the years; it was 1.7% in 2005-2009 and 0 % in 2010-2015 (p = 0.246). Conclusion: The prevalence of eclampsia cases has decreased over the years. Maternal mortality attributed to eclampsia has also declined. The early diagnosis and treatment of eclampsia have resulted in the increase of premature deliveries. The perinatal mortality rate showed a slight decrease throughout the years (p = 0.238); however, it is not at a desirable rate compared to developed countries.